Rs485 communication parameters (dip switch 1), Dip switch 1 setting description, Dip switch 1 unit number – Panasonic WV-CW964 User Manual

Page 15: Dip switch 1 unit number dip switch 1 unit number

background image

-15-

* When using the Unit Number 1 to 96 setting, the unit number setting needs to be configured using the RS485 SET UP menu. For details

about configuring this setting, see step 2 and page 21.

* Turning on power when this setting is selected causes the RS485 SET UP menu to appear during the initialization routine.

1

2

3

4

ON

5

6

7

8

DIP Switch 1

Unit

Number

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

DIP Switch 1

Unit

Number

DIP Switch 1

Unit

Number

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

RS485 Communication Parameters (DIP Switch 1)

Configuring DIP Switch 1 as shown below resets communication parameters to their factory default settings. You can
then change the settings as desired.

1

2

3

4

ON

5

6

7

8

DIP Switch 1

Setting Description

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

1

2

3

4

ON

5

6

7

8

This setting resets communication parameters to the factory default settings.

BAUD RATE : 19 200 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit

BAUD RATE : 9 600 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit

BAUD RATE : 4 800 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit

ON

Perform the following steps to use this setting.

(1) Turn off the camera and use DIP Switch 1 to configure RS485 communication parameters as shown above.
(2) Turn on the camera.

This applies the setting you configured in step (1).

(3) Turn off the camera, use DIP Switch 1 to set the unit number (pages 14 and 15), and then turn the camera

back on again.