beautypg.com

Safety, Tourclass, Protection – Peavey 8002 User Manual

Page 32

background image

Pro II owner’s manual

p. 30

safety

6

TourClass

®

protection

Every model in the Pro II Series incorporates TourClass protection fea-
tures. Derived from Crest Audio’s extensive experience with the world’s
largest sound rental companies, the TourClass group of circuits sets the
industry standard for assured protection of internal amplifier circuits and
all connected loads.

ACL

ACTIVE CLIP LIMITING

At the amplifier’s full power limit, or clipping point,

ACL

will be activated.

This is indicated by illumination of the

ACL LED

.The channel gain is auto-

matically reduced, protecting the loudspeakers from potential damage from
the high power, continuous square waves that would otherwise be pro-
duced.

ACL

may be activated by uncontrolled feedback, oscillations, improp-

er equipment gain settings, or an equipment malfunction upstream from
the amplifier. Only steady or excessive clipping

(

not normal program tran-

sients

)

will trigger

ACL.

The circuit is virtually transparent in operation and

full signal bandwidth is maintained.

IGM

INSTANTANEOUS GAIN MODULATION

IGM

is an innovative circuit that allows the amplifier to operate safely into

loads as low as 2 ohms.When the amplifier sees a load that overstresses the
output stage, the

IGM

circuit adjusts the channel gain to a safe level. Like

ACL,

the

IGM

circuit is inaudible in normal use.In addition,if extreme and sustained

low impedance is encountered, the amplifier’s output relay will open.

AutoRamp

Auto Ramp operates every time the amplifier is turned on or is reactivated
after a protect condition is corrected. This exclusive Crest Audio feature
gradually increases gain to the attenuator setting avoiding unnecessary stress
on the loudspeakers.

Thermal

Abnormally high heat sink temperatures will engage the

Protect

circuit for the

overheating channel only.

(

An output relay disconnects the loudspeakers until

nominal temperature range is restored.

)

During this time, the

Status

LED

will

light red. If the power supply gets too hot, its thermal sensing circuit will dis-
connect both channel outputs. During this time, the

Active

LED

will extin-

guish, the Status

LED

will remain red, and the cooling fan will continue run-

ning at high speed. Normal operation resumes once the power supply cools
to a safe level.

Short Circuit

If an output is shorted

(

i.e., defective speakers or crossed speaker wires

)

the

IGM

and thermal circuits will automatically protect the amplifier.The

IGM

cir-

cuit senses the short circuit as an extremely stressful load condition and
attenuates the signal, protecting the channel’s output transistors from over-
current stress. If the short circuit remains, the load will be disconnected by
the thermal protection circuitry

(

the output relay opens

)

.