Eq series, High performance commercial pump – Pentair EQ SERIES User Manual
Page 2

Pump Body
Volute type, back pull-out design.
•
Port Size
6" – ANSI 150 bolted flange suction port.
1
4"– ANSI 150 bolted flange discharge port.
1
•
Material - Volute & Motor Adapter
Noryl
®
.
•
Impeller
Noryl
®
enclosed design.
•
Base
6061 Aluminum design, slotted for mounting ease.
•
Corrosion Prevention
All-plastic pump for maximum hydraulic performance
and corrosion prevention.
Hair and Lint Strainer
•
Material
Separate bolt-on Noryl
®
body with plastic
basket, Lexan
®
lid, and stainless steel bolts.
•
Size
6" ANSI 150 bolted flange suction and
discharge ports.
Pump Maximum Limits
Liquid Temperature: 104º F
Ambient Air Temperature: 104º F
Motor
Standard JM type.
•
Frame Size
NEMA “C” flange. 230/460V are open
drip-proof design.
•
Shaft
303 Stainless steel construction.
•
Design
3 to 15 HP, 3500 RPM, JM open drip-proof, continuous
duty, three-phase and single-phase (5 and 71/2 HP only).
•
Bearings
Double shielded, single row, deep groove type,
permanently lubricated.
•
Thermal Overload Protection
All models require external thermal overload protector.
Electrical
•
Power Supply Required
Three-phase pumps are 208 – 230/460. 3, 5 and 71/2 HP
single-phase models are available in 230V, 60 Hz. only.
For detailed efficiency curves for each model, please contact the factory.
1
Use ANSI class 150 plastic flange and
1
⁄
8
" thick class 150 full flange
gasket to make connection.
EQ Series
®
High Performance Commercial Pump
MatEriaLS and dESign
Performance curves
EQ Series
®
Performance curve
EQ Series
®
Waterfall
™