Profoto Pro-7 User Manual
Page 24
Pro-7a/1200
Pro-7a/2400
Guide numbers in metres/feet at 100 ASA
with a Magnum 50° Reflector
140/460
201/660
Flash Duration (t 0.5) at:
Pro-7 head
Pro-7 twin
Pro-7 head
Pro-7 twin
4800 Ws
–
–
–
1/1600 sek
2400 Ws
–
1/2200 sek
1/1600 sek
1/2200
1200 Ws
1/2200 sek.
1/3200
1/2200
1/3200
600 Ws
1/3200
1/5300
1/3200
1/5300
300 Ws
1/5300
1/8000
1/5300
1/8000
150 Ws
1/8000
1/12000
1/8000
1/8000
75 Ws
1/12000
1/12000
1/8000
–
37,5 Ws
1/12000
–
–
–
PLEASE NOTE: With Pro-7 twin and two Pro-7a generators the recharging time is approx. twice as fast.
Recharging Time at:
230V/50Hz
0.08 - 0.7 sek.
0.12 - 1.4 sek.
120V/60Hz
0.15 - 0.8
0.17 - 1.5
200V/50Hz
0.10 - 1.1
0.14 - 2.1
100V/50Hz
0.17 - 1.4
0.19 - 2.7
Power Consumption (Turbo)
200 - 240V, 50/60Hz
10 A (fuse)/generator
100 - 120V, 50/60Hz
15 A (fuse)/generator
Maximum Modelling Light
Maximum 500 W per head or totally 1500 W when three heads are used. Please note that the
modelling light output automatically adjusts itself to the voltage in question (100 - 240V).
Size & weight, generators
Pro-7a/1200
Pro-7a/2400
Width x length x height, cm/in
24 x 17 x 34
24 x 17 x 40
9
1
/
2
x6
3
/
4
x13
3
/
8
9
1
/
2
x6
3
/
4
x15
3
/
4
Weight, kg/lb.
9 / 20
12 / 26
Size weight, lamp head
Length (incl. glass cover) x diameter, cm/in:
26 x 10 cm/10” x 4”
Weight, kg/lb.
2.4 / 5
Gas Generator
Most gas generators with an output of 3000 W or more can always power Profoto generators.
Please note that you always need a ProGas unit between the gas generator and the Profoto gen-
erator in order not to damage these two units (only 230V). For more information please contact
your local dealer.
Technical Data
24