PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Fuse blown, circuit breaker
tripped.

1. Check fuse box for blown

fuse and replace as

necessary. Reset circuit

breaker. Do not use a

fuse or circuit breaker

with higher rating than

that specified for your

particular branch circuit.

2. Check for proper fuse. You

should use a time delay

fuse.

3. Check for low voltage

conditions and/or proper

extension cord.

4. Disconnect the other

electrical appliances from

circuit or operate the

compressor on its own

branch circuit.

Motor overload protection
switch has tripped

Let motor cool off and
overload switch will
automatically reset.

Tank pressure exceeds
pressure switch "cut-in"
pressure.

Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.

Loose electrical
connections.

Check wiring connection
inside pressure switch and
terminal box area.

Have checked by a Trained
Service Technician.

Check valve stuck open.

Remove and clean, or replace.

Refer to the "To Replace or

Clean Check Valve" in the

"Service and Adjustment"

section.

Possible defective motor
or starting capacitor.

Have checked by a Trained

Service Technician. Do not

operate the compressor in

the paint spray area. See

flammable vapor warning.

Paint spray on internal
motor parts.

Bleed the line by pushing the

lever on the pressure switch

to the "OFF" position; if the

valve does not open, contact a

Trained Service Technician.

Pressure release valve on
pressure switch has not
unloaded head pressure.