beautypg.com

Porter-Cable CLFRP350 User Manual

Page 21

background image

21- ENG

A10055

PROBLEM

CAUSE

CORRECTION

Compressor is
not supplying
enough air
to operate
accessories.

Pressure reading
on the regulated
pressure gauge
(if equipped)
drops when an
accessory is
used.

It is normal for "some"
pressure drop to occur.

If there is an excessive amount
of pressure drop when the
accessory is used, adjust the
regulator as instructed in the
Operation section.
NOTE: Adjust the regulated
pressure under flow conditions
(while accessory is being
used).

Possible defect in safety
valve.

Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.

Air leak from
safety valve.

Clean or replace. See "Air
Filter" paragraph in the
"Maintenance" section.

Dirty air filter.

Restricted air
intake

Damaged regulator

Have checked by a Trained
Service Technician.

Regulator knob
has continuous
air leak.

Regulator will
not shut off air
outlet.

Damaged regulator

Have checked by a Trained
Service Technician.

Possible defect in safety
valve.

Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.

Prolonged excessive use
of air.
Compressor is not large
enough for air requirement.

Hole in hose.

Check valve restricted.

Air leaks.
Restricted air intake filter

Decrease amount of air usage.

Check the accessory air

requirement. If it is higher than

the SCFM or pressure supplied

by your air compressor, you

need a larger compressor.

Check and replace if required.
Check and replace if required.

Remove and clean, or replace.

Refer to the "To Replace or

Clean Check Valve" in the

"Service and Adjustment"

section.
Tighten fittings.
Clean or replace air intake

filter. Do not operate the

air compressor with the

filter removed. Refer to the

"Air Filter" paragraph in the

"Maintenance" section.