PGS K-40 User Manual
Page 19
Figure 17 Leak Checking the Valve Connection
4. If no gas leaks appear (bubbles), turn off gas
supply and continue assembly. IF YOU ARE UNABLE
TO STOP A LEAK, CONTACT YOUR LOCAL
DEALER FOR ASSISTANCE BEFORE
PROCEEDING.
Figure 15
LP Hose/Regulator Connection
5. If there are no gas leaks, attach the collar box with
AGA/CGA rating sticker attaching to the pedestal as
follows (see Fig. 18):
• Remove two #8 x 1/2" screws from bottom of
control panel leaving attached Tinnerman clips.
• Attach two Tinnerman clips (found in pedestal parts
bag) to lower two holes in the collar box.
• Place collar box inside opening in pedestal.
• Insert two #8 x 1/2" screws (found in pedestal parts
bag) though pedestal into collar box and Tinnerman
clips.
• Insert two #8 x ½" screws removed from control
panel back into control panel going first through top of
collar box.
Figure 16
Natural Gas Hose Connection
2. TURN YOUR GAS SUPPLY (LP OR
NAT) ON AND TEST ALL FITTINGS FOR
LEAKS. BEFORE ATTEMPTING TO LIGHT
GRILL, BE CERTAIN BOTH VALVES ARE IN THE
OFF POSITION. TURN GAS SUPPLY ON (leaving
both control knobs in the "OFF" position) AND
CHECK ALL CONNECTIONS WITH A SOLUTION
OF 50% LIQUID SOAP, 50% WATER. SOLUTION
CAN BE SPRAYED ON WITH A SPRAY BOTTLE
(see Fig. 17) OR PAINTED ON ALL CONNECTIONS
WITH A BRUSH. IF BUBBLES APPEAR, TURN OFF
GAS, TIGHTEN FITTINGS AND TRY AGAIN.
NEVER CHECK FOR LEAKS WITH A MATCH OR
FLAME.
Figure 18 Collar box installation to pedestal and
control panel
19