beautypg.com

20 troubleshooting guide, Mulitple system, Symptom distance possible possible cause solution – Peavey PCX-V12 User Manual

Page 20: Symptom distance possible action cause

background image

20

TROUBLESHOOTING GUIDE

Symptom

Distance

Possible Possible
Cause

Solution

No AF signal

Any

low transmitter

replace battery

and no RF signal

battery voltage

No AF signal

long

out of range

move transmitter

and no RF signal

closer to receiver or
obstecles

No AF signal

any

microphone or

check input source

but normal RF signal

other input source

Distortion with no

any

low transmitter

replace battery

AF peak indication

battery voltage

Noise with low AF

any

strong RFI

identify source and

signal and normal

eliminate, or change

RF signal

frequency of wireless
microphone system

Intermittent AF signal

long

out of range

move transmitter and

low RF signal

closer to RCV

Intermittent AF and

average

obstructions

remove obstructions

RF signals

in signal path

or reposition transmitter
and/or RCV

MULITPLE SYSTEM

Symptom

Distance

Possible Action
Cause

Distortion on two

any

units on same

change frequencies

or more systems without

frequency

Distortion on one

transmitter-

transmitter + transmitter change frequencies

or more systems without

transmitter short

intermod

Distortion on one

transmitter-

transmitter + transmitter increase transmitter

or more systems without

transmitter short

intermod

to transmitter distance

transmitter-receiver

transmitter +transmitter

change frequencies

short

receiver intermod

Distortion on one or more

transmitter-receiver

transmitter +transmitter

increase transmitter

systems without

short

receiver intermod

to receive distance

AF peak indication