20 troubleshooting guide, Mulitple system, Symptom distance possible possible cause solution – Peavey PCX-V12 User Manual
Page 20: Symptom distance possible action cause
20
TROUBLESHOOTING GUIDE
Symptom
Distance
Possible Possible
Cause
Solution
No AF signal
Any
low transmitter
replace battery
and no RF signal
battery voltage
No AF signal
long
out of range
move transmitter
and no RF signal
closer to receiver or
obstecles
No AF signal
any
microphone or
check input source
but normal RF signal
other input source
Distortion with no
any
low transmitter
replace battery
AF peak indication
battery voltage
Noise with low AF
any
strong RFI
identify source and
signal and normal
eliminate, or change
RF signal
frequency of wireless
microphone system
Intermittent AF signal
long
out of range
move transmitter and
low RF signal
closer to RCV
Intermittent AF and
average
obstructions
remove obstructions
RF signals
in signal path
or reposition transmitter
and/or RCV
MULITPLE SYSTEM
Symptom
Distance
Possible Action
Cause
Distortion on two
any
units on same
change frequencies
or more systems without
frequency
Distortion on one
transmitter-
transmitter + transmitter change frequencies
or more systems without
transmitter short
intermod
Distortion on one
transmitter-
transmitter + transmitter increase transmitter
or more systems without
transmitter short
intermod
to transmitter distance
transmitter-receiver
transmitter +transmitter
change frequencies
short
receiver intermod
Distortion on one or more
transmitter-receiver
transmitter +transmitter
increase transmitter
systems without
short
receiver intermod
to receive distance
AF peak indication