TROUBLE SHOOTING

SYMPTOM A: NO AC POWER OUTPUT, THE RED LED LIGHTS.

SYMPTOM B: NO AC POWER OUTPUT, NO LED LIGHTS ARE ON.

6

POSSIBLE CAUSES

SUGGESTION

The connected AC products are rated at more than 600 Watts

(PINV4) , 800 Watts (PINV5) or 1000 Watts (PINV6), the

overload shutdown occurred.

Use the product with a total power rating

less than 600 Watts (PINV4) , 800 Watts

(PINV5) and 1000 Watts (PINV6) .

The connected AC products are rated at less than 600 Watts

(PINV4) , 800 Watts (PINV5) or 1000 Watts (PINV6), the high

starting surge causes the overload shutdown.

Use the product not exceeds the inverter's

surge capacity, 1200 Watts (PINV4) , 1600

Watts (PINV5) and 2000 Watts (PINV6) .

The battery is discharged (alarm sounds)

Recharge battery.

The inverter overheated

Turn off the inverter and allow to cool for

15 minutes. Clear blocked fan (PINV4 /

PINV5 / PINV6) or remove the objects

covering the ventilation.

POSSIBLE CAUSES

SUGGESTION

The fuse of inverter is blown

Check to make sure the inverter is

connected to a power source with correct

voltage and polarity.

Replace fuse.

The inverter has been connected with reverse DC input

polarity.

The inverter needs repairment

if the probable damage has occurred.