BATTERY OPERATING TIME

The vehicle batteries are not intended for constant deep discharge, they are designed to provide brief

periods of very high current needed for engine starting. It is strongly recommended to start the vehicle

every hour or two to recharge battery before its capacity drops too low. Operating the inverter from a

vehicle battery until the low voltage alarm sounds will shorten the battery's life.

The inverter can operate whether or not the vehicle's engine is running, but the normal voltage drop that

occurs during starting may trigger the inverter's low voltage shutdown feature.

The use of a deep discharge battery is strongly advised for longer operating times. Its capacity should be

selected based on the desired operating time.

5

PROTECTION

SYMPTOMS

The input reverse polarity

The low voltage battery (below DC 10V)

The high input voltage (over DC 15.6V)

The overload

The overheat

PROTECTION

The fuse blown.

The unit auto shutdown.

The alarm sounds.

The RED LED lights.

The unit auto shutdown.

The RED LED lights.