16 March 2006

Page 24 of 33

Vega Gateway Scenarios.

©2005-2006 VegaStream Ltd.

Examples are given in best faith – ensure that you check the capabilities of systems before

deploying them, especially the functionality of devices not designed and delivered by VegaStream.

9.b Analog breakout to the PSTN – e.g. for a company or for a PSTN toll bypass

A Vega FXO can be connected directly to PSTN lines.

Calls from VoIP into the PSTN specify the desired destination number by sending DTMF tones
into the PSTN.

Considerations

• Disconnect supervision is only supported by physical signalling – line current reversal or

loop current disconnect; no voice or tone detect can be configured on the Vega to indicate
end of call

• Answer supervision is only supported by physical signalling – line current reversal

• Calls received on the telephony interface arrive with no dialled number information as

analog signalling just uses a ringing voltage to indicate the call arrival.

• Different impedances are required for ‘approved’ connection in different countries. Europe

should have the Vega FXO interface configured for CTR21 impedance; the US should have
the interface configured for 600R operation. 900R impedance is also available.