Logic symbol, Function table, Absolute maximum ratings 1, 2 – Philips CBT6800 User Manual
Page 3: Recommended operating conditions

Philips Semiconductors
Product data
CBT6800
10-bit bus switch with precharged outputs
for live insertion
2003 Sep 12
3
LOGIC SYMBOL
BIASV
A1
A10
SA00536
B1
B10
OE
13
FUNCTION TABLE
OE
B1 - B10
FUNCTION
L
A1 - A10
Connect
H
BIASV
Precharge
H = HIGH voltage level
L
= LOW voltage level
Z = HIGH impedance “off” state
ABSOLUTE MAXIMUM RATINGS
1, 2
SYMBOL
PARAMETER
CONDITIONS
RATING
UNIT
V
CC
DC supply voltage
-0.5 to +7.0
V
I
IK
DC input diode current
-50
mA
V
I
DC input voltage
3
-1.2 to +7.0
V
I
SW
DC clamp diode current
V
O
< 0
-50
mA
T
stg
Storage temperature range
-65 to 150
°
C
BiasV
DC voltage range
-0.5 to 6.0
V
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2. The performance capability of a high-performance integrated circuit in conjunction with its thermal environment can create junction
temperatures which are detrimental to reliability. The maximum junction temperature of this integrated circuit should not exceed 150
°
C.
3. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
RECOMMENDED OPERATING CONDITIONS
LIMITS
SYMBOL
PARAMETER
Min
Max
UNIT
V
CC
DC supply voltage
4.5
5.5
V
BIASV
DC supply voltage
1.3
V
CC
V
V
IH
HIGH-level input voltage
2.0
—
V
V
IL
LOW-level Input voltage
—
0.8
V
T
amb
Operating free-air temperature range
-40
+85
°
C