18 advanced setup – Pioneer V8000 User Manual
Page 69

Operating Modes
- 62
Format :
WW
7 fields integer
Explanation :
The real time clock may be set using the following format:
YY
the last two digits of year
MM month
DD date
WW day, 00 means Monday, 06 means
Sunday
HH
hour 24-hour format
MM minute
SS second
NOTE: Input the 7-bytes integer as a single entry. If an integer is less than 7-
bytes in length, the player returns an error message.
Execution :
String
Status Return
DVD player
WW
Set Real Time Clock setting
mode
06051500123456
Sets Monday, May 15t,
12:34:56, 2006
6.18 Advanced
Setup
Function
: current setting of Advanced Setup Menu is rewritten
Format :
Integer
MS
Explanation : The command rewrites the Advanced Setup Menu settings,
which is expressed as an integer. The integer value is made up of the sum of
the selected arguments. The player returns an error code if the command is
issued while the Advanced Setup Menu is on the screen. The factory default
value is 0.
The Advanced Setup Request command (?S) reveals the current setting.
Description
Argument Function
0 1
1 WEEKLY
TIMER
OFF
ON
2
POWER ON START
OFF
ON
4
TITLE PLAY MODE
SINGLE
ALL
8
16
REPEAT MODE
(0) OFF, (8) CHAPTER
(16) TITLE, (24) DISC *1)