IntelliFlo Installation and User’s Guide

Mo Flo (Modulation Output Flow)

M.O. Flo (Modulated Output Flow) is specifically designed for Pentair branded heaters with an
IntelliComm, although it can be used for other functions, such as water effects. This feature allows you to
have flexibility in flow control if the filter cycle flow is less than needed for certain devices. M.O. Flo also
allows you to program intervals of flow separated by a specific duration which can be useful for water
effects.

To setup the M.O. Flow option:

1. Ensure that the green power LED is on and the pump is stopped.

2. Press the Menu button. Press the Up or Down arrows to select the “Features” menu. Press the

Down arrow button to select M.O. Flow. Press the Select button to access the M.O. Flow menu
settings. The M.O.Flow “Activation” setting is displayed.

3.

To enable M.O. Flow:

Press the Select button then the Down arrow button to select Enabled if not

already selected. Press the Enter button to save the setting.

4.

To set the flow rate for M.O. Flow:

Press the Down arrow button to select “Set Flow” setting. Press

the Select button to access the setting. To edit the flow rate (GPM) setting, see step 6.

5.

To set the run and interval time for M.O. Flow:

Press the Down arrow button to select “Set Run

Time” or Set Interval Time” setting. Press the Select button to access the setting. To edit the start
and stop time, see step 6.

6. Press the Select button to change the current value.

7. To change the value, press the Left and Right arrows to select which digit to modify, then use the Up

and Down arrows to change the selected digit.

8. When you are done, press the Enter button to save the changes. To cancel any changes, press the

Escape button to exit edit mode without saving.

The following graphical representation shows when the M.O. Flo feature is enabled.

Flow

Run time Interval time

Programmed
Cycle

M.O.Flo
set Flow

Time

Enable/ Disable Set Flow Set Run Time Set Interval Time

Filter

Vacuum

Back

Wash

Manual

Enter

Select

Reset

Feature

2

Feature

1

Men

u

Escape

On

Warn.

Alarm

IntelliFlo

®

M.O. Flo

M.O. Flo

7:29

7:29

Disabled

Disabled

Start
Stop

Activation

Activation

Filter

Vacuum

Back

Wash

Manual

Enter

Sele

ct

Start
Stop

Reset

Feature

2

Feature

1

Men

u

Escape

On

Warn.

Alarm

IntelliFlo

®

M.O. Flo

M.O. Flo

7:29

7:29

Set Flow

Set Flow

50.GPM

50.GPM

Filter

Vacuum

Back

Wash

Manual

Enter

Select

Start
Stop

Reset

Feature

2

Feature

1

Men

u

Escape

On

Warn.

Alarm

IntelliFlo

®

M.O. Flo

M.O. Flo

7:30

7:30

Set Run Time

Set Run Time

0:01

0:01

Filter

Vacuum

Back

Wash

Manual

Enter

Select

Start
Stop

Reset

Feature

2

Feature

1

Men

u

Escape

On

Warn.

Alarm

IntelliFlo

®

M.O. Flo

M.O. Flo

7:31

7:31

Set Interval Time

Set Interval Time

1:00

1:00

Filter

Vacuum

Back

Wash

Manual

Enter

Select

Reset

Feature

2

Feature

1

Men

u

Escape

On

Warn.

Alarm

IntelliFlo

®

Features

7:22

M.O. Flo

Start
Stop