Limiting values – Philips TDA1562ST User Manual
Page 9

2003 Feb 12
9
Philips Semiconductors
Preliminary specification
70 W high efficiency power amplifier
with diagnostic facility
TDA1562Q; TDA1562ST;
TDA1562SD
Fig.5 Behaviour as a function of temperature.
handbook, full pagewidth
class-H
maximum output
voltage swing
diagnostic
output
status I/O: high
status I/O: open
MGL266
class-B
0
HIGH
LOW
status I/O
output
HIGH
MID
LOW
120
145
Tj (
°
C)
150
160
100
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134).
Notes
1. When operating at V
P
> 16 V, the output power must be limited to 85 W at THD = 10% (or minimum load is 6
Ω
).
2. T
j
is a theoretical temperature which is based on a simplified representation of the thermal behaviour of the device.
T
j
= T
c
+ P
×
R
th(j-c)
, where R
th(j-c)
is a fixed value to be used for the calculation of T
j
. The rating for T
j
limits the
allowable combinations of power dissipation P and case temperature T
c
(in accordance with IEC 60747-1).
SYMBOL
PARAMETER
CONDITIONS
MIN.
MAX.
UNIT
V
P
supply voltage
operating; note 1
−
18
V
non-operating
−
30
V
load dump; t
r
> 2.5 ms; t = 50 ms
−
45
V
I
OSM
non-repetitive peak output current
−
10
A
I
ORM
repetitive peak output current
−
8
A
V
sc
short-circuit safe voltage
−
18
V
T
stg
storage temperature
−
55
+150
°
C
T
amb
ambient temperature
−
40
−
°
C
T
j
junction temperature
note 2
−
150
°
C
P
tot
total power dissipation
−
60
W