Battery runtimes (in minutes)

iSeries

pSeries

Storage

Cluster

870

890

655

670

690

2105

1350

1600

with

CEC +

CEC + CEC +

1

2

3

expansion

I/O

I/O

I/O

node

nodes

nodes

up to

8 way

32 way

standard enclosure

10 kVA 15 kVA 20 kVA 16 way 16 way 32 way

1 I/O

2 I/O

3 I/O

32 way

1 I/O

3 I/O

7 kW

10.5 kW 14 kW

6.8 kW 4.9 kW 8.3 kW 3.2 kW 6.4 kW

9.6 kW 6.5 kW

3.2 kW 10.5 kW

6.4 kW

13.8 kW

Internal battery

45

26

17

48

79

31

110

50

27

49

110

26

50

17

(1) External
battery cabinet

90

65

48

98

150

75

240

110

70

108

240

65

110

48

(2) External
battery cabinets

155

90

75

166

240

130

400

180

96

172

400

90

180

75

Contact Powerware for runtime, application or configuration assistance.

A DC rated circuit breaker in each battery cabinet allows
multiple battery strings to be serviced independently of each
other, assuring back up power is always available to the UPS

Removable battery slide-out tray assembles provide “front
access only” and reduce battery maintenance time.

Manufacturer-supplied wiring with quick disconnects provides
plug-and-play capability for line-up and match configurations.

Quick disconnects between battery tray assemblies reduce
battery maintenance time.

Ī

Battery cabinets may be daisy-chained together for extended battery runtimes,

(up to 2).

Ī

Integral configuration, which line up and match, is standard.

1

Ī

Front-access-only enhances servicing and installation.

Ī

Slide trays and modular battery packaging makes periodic servicing easy.

Ī

Cabinets are UL 1778 listed.

Ī

Flame retardant batteries meet UL 94V2 for computer room installations.

Ī

Wiring installation.

2

Powerware offers a full line of battery cabinets for the Powerware P93.

Extended Battery Cabinets

1. Battery cabinets can be configured as line up and match or
remotely located. Customer must provide wiring for remotely
located cabinets. 2. If concurrent to P93 Field Installation,
Powerware PN 103003671, IBM PN 97P3604.

Calculating runtime - a guide

Typical runtime is 15 minutes
Formula (runtime in minutes) = [business + (2 x system shutdown) + safety]
Business = _____
Shutdown ____ x 2 = _____
Safety = _____
Total = _____

Powerware

IBM

IBM

Per P93

Part Number

Feature Code

Part Number

Minimum

Maximum

External Battery Cabinet

A13031

6635

97P2663

0

2

Additional options

Ī

Input/output galvanic isolation

Ī

Voltage matching transformers

Ī

Remote status panel

Ī

Remote EPO button

Contact