1606m monitor console, Specifications subject to change without notice – Peavey RQ 1606M User Manual
Page 14
Function
Input z
Input Gains
Input Levels^
Bal./
Connector
(ohms)
Setting
Min**
Nominal*
Max
UnBal.
Min
XLR Input
2.2 k
Max gain
-77 dBu
-57 dBu -35 dBu
Bal.
XLR: Pin 1 Gnd
(150 ohms)
(57 dB)
Pin 2 (+),
Pin 3 (-)
Min. gain
-30 dBu
-10 dBu +12 dBu
(10 dB)
Hi-Z
10 k
Max. gain
-77 dBu
-57 dBu -35 dBu
Bal.
1/4" TRS: Tip (+),
(10 k ohms)
(57 dB)
Ring (-),
Sleeve Ground
Min. gain
-30 dBu
-10 dBu +12 dBu
(10 dB)
Insert
22 k
N/A
-20 dBu
0 dBu +22 dBu
Unbal. 1/4" TRS: Tip Send,
Return
(0 dB)
Ring Return,
Sleeve Ground
Monitor Aux
10 k
N/A
-20 dBu
0 dBu +21 dBu
Ba.l
1/4" TRS: Tip (+),
Input
(0 dB)
Ring (-),
Sleeve Ground
Talkback
2.2 k
N/A
-54 dBu
-30 dBu -8 dBu
Bal.
XLR: Pin 1 Gnd
Mic
(30 dB)
Pin 2 (+),
Pin 3 (-)
RQ
®
1606M Monitor Console
Specifications:
Input Specifications:
0 dBV=1V (RMS)
** Min input level (sensitivity) is the smallest signal that will produce nominal output (0 dBu) with channel and master
level controls set for maximum gain.
* Nominal settings are defined as all controls set at 0 dB (or 50% rotation for rotary pots) except the gain adjustment pot,
which is as specified.
^ Input 20 dB pad is not included in these levels.
14