beautypg.com

Wire gauge chart – Peavey IA 400V User Manual

Page 12

background image

Stranded

Power

Power

Power

Cable

Wire

Loss

Loss

Loss

Length

Gauge

Into

Into

Into

(Feet)

(AWG)

8 ohms

4 ohms

2 ohms

5'

18 AWG

.79%

1.58%

3.16%

16

.05

1.0

2.0

14

.31

.62

1.24

12

.20

.40

.80

10

.125

.25

.50

10'

18 AWG

1.58%

3.16%

6.32%

16

1.0

2.0

4.0

14

.62

1.25

2.50

12

.40

.80

1.6

10

.25

.50

1.0

40'

18 AWG

8%

12.6%

25.2%

16

4.0

8.0

16.0

14

2.5

5.0

10

12

1.60

3.2

6.4

10

1.0

2.0

4.0

8

.625

1.25

2.50

80'

16 AWG

8.0%

16.0%

32.0%

14

5.0

10.0

20.0

12

3.2

6.4

12.8

10

2.0

4.0

8.0

12

WIRE GAUGE CHART