Resolution / Frequency

This function displays the resolution and frequency of the detected in-
put signal.

When an analog RGB, DVI analog, or DVI digital signal is input, there will not
be a display unless input selection of RGB or DVI has already been made.

Factory Default

Lamp Timer Reset

Resolution

1024 768

75Hz 60kHz

12h

Frequency

Lamp Timer

Status

Lamp Timer

This displays the lamp timer.

This projector has an Eco mode function. The lamp life will differ between
Normal mode and Eco mode.

Lamp Life
Use only in Normal mode: approx.3000 hours
Use only in Eco mode: approx.4000 hours
* Lamp life will differ when there has been switching between the modes.

• When Lamp Life Has Been Reached

“Replace the Lamp Cartridge” is displayed on the screen for 10 seconds in
a 1-minute interval.
Please replace the lamp with a new one.
See "Replacing the Lamp Cartridge" on Page E-62 for information about
lamp cartridge replacement.

• When Over 100 Hours Have Elapsed Since Reaching Lamp Life

(Including Eco Mode)
[Warning!! System Shutdown] is displayed for 10 seconds and the power is
switched off. Pressing the POWER button under this condition will not switch
on the power. Please replace the lamp cartridge.