200-2341
25
1. Perform first change at 25 hours.
M
M
M
M
A
A
A
A
II
II
N
N
N
N
T
T
T
T
E
E
E
E
N
N
N
N
A
A
A
A
N
N
N
N
C
C
C
C
E
E
E
E
Every month
or 15 hours
Every 6 months
or 100 hours
Every year or
300 hours
Every 2 years
or 500 hours
Engine Oil
Check
X
Change
X
1
Engine Oil Filter
Change
X
Oil Cooler
Check and Clean
X
Engine Air Filter
Check
X
Change
X
Battery
Check and Clean
X
Battery Charger
Check
X
Spark Arrestor
Check and Clean
X
Spark Plugs
Check
X
Replace
X
Valve Clearance
Check and Adjust
X
Generator Output Frequency
Check and Adjust
X
Fuel System
Check
X
Cooling Air Openings
Check
X
To ensure reliable generator operation, it is critical to
periodically inspect all components. The following chart
is provided as a guide for service check intervals. When
the generator is operated under excessively hot, or dusty
conditions, shorten service intervals according to the
severity of the conditions encountered. To perform
periodic inspections or maintenance, refer to the
procedures listed in the following sections. A qualified
generator service technician should perform inspections
or adjustments requiring specialized tools or training.
Users unfamiliar with any of the listed procedures should
contact an authorized dealer for servicing assistance.
Maintenance Item