Now, right click in the A
CTIVATED
C
OMMAND
column for Logic Input 1 and select I
NSERT
, I
NPUT
, 1,
M
UTE
, O
FF
. Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute
Input 1.
Now, right click in the D
EACTIVATED
C
OMMAND
column for Logic Input 1 and select I
NSERT
, I
NPUT
, 1,
M
UTE
, O
N
. Now, whenever the switch goes Active High (+ 5V DC), the Vortex Device will mute
Input 1.
Do not assign any command to the H
ELD
C
OMMAND
column.
If you are successful, you should see this on the screen: