Now, right click in the H
ELD
C
OMMAND
column for Logic Input 1 and select I
NSERT
, I
NPUT
, 1, M
UTE
,
O
FF
. Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute Input 1.
If you are successful, you should see this on the screen:
Make sure that the physical wiring works by pressing and holding the membrane switch. You
should see the LED above the pin assignment lit in green:
Repeat the above process for each MX392 microphone that you want to connect to the Vortex
Device.