5

CONTROL PANEL AND BASIC OPERATION:

Power Input:

The power required to operate the PowerLight 1250, 1250DR or 2500DR is 105 to 125
volts AC, 60 Hz, 10 Amp. The power cord has a 125V, 10 Amp. rating. Replacement
cords or extension cords rated for less amperage may overheat and should not be used
with PowerLights.

Circuit Protection:

Circuit protection automatically protects this appliance from excessive damage due to
circuit or component failure. Operation exceeding the rated cycle of the appliance may
cause the fuse to open. [Always replace fuse with same rating of fuse.] An additional
thermal protector is located inside the PowerLight and may open, if the rated duty cycle
is exceeded. A cooling off period of 10 to 45 minutes is required to reset the thermal
fuse.

To replace a blown fuse (power cord must be disconnected), simply unscrew the fuse
holder cap (bottom of unit) and replace the exposed fuse with a new fuse. If fuses
continue to blow, contact your dealer or qualified service person. (See specification
section for fuse replacements)