beautypg.com

Megatherm, High performance gas fired commercial pool heaters, Additional design advantages include – Pentair 5001825 User Manual

Page 4

background image

High Performance Gas Fired Commercial Pool Heaters

6/08 Part #P1-355

the Perfect Combination of Accurate Control,

Efficiency, and Long Life

MegaTherm

®

is packed with performance features designed specifically

for the commercial, institutional, and large residential pool market.
The primary/secondary pump and control (Models 500–1825) feature
an electronic controller with a solid state sensor and adjustable
differential for accurate temperature control. Inlet water is preheated
to eliminate condensation, and a constant velocity in the heat
exchanger increases tube life. The diverter valve has been eliminated
in the pool circulation line, resulting in lower installation and operating
costs. And, inlet and outlet thermometers with ±1% accuracy allow
precise set-up and temperature rise monitoring.

Additional Design Advantages Include:

Control system includes automatic temperature control, temperature

limit, gas pressure regulator, redundant electric gas valve, water
flow sensing, electronic flame safety supervision and manual gas
shut-off valve. The standard control system operates on 24 VAC
with a 120 VAC power supply. Standard units are intermittent
(spark) ignition.

Working pressure of 160 psi complies with Section IV of the ASME

®

Boiler and Pressure Vessel Code. Units are registered with the

National Board of Boiler and Pressure Vessel Inspectors.

Pressure relief valve is ASME

®

rated and is selected to provide

discharge capacity in excess of unit heating input.

Combustion chamber is cast refractory with a 2000° F (1093° C)

working temperature.

Burners are atmospheric type constructed of AISI alloy 430 (models

500–1825) or AISI 439 (models 2000–5000) stainless steel.

Chassis and jacket parts are of galvanized steel meeting ASTM

®

Standard for G90 coating. Exterior is finished with acrylic paint,
thermoset at 325° F (163° C).

Integral flow control valve on models 2000–5000 accepts flows

up to 300 GPM.

©2008 Pentair Water Pool and Spa, Inc. All rights reserved.

1620 Hawkins Avenue
Sanford, NC 27330
Phone: 800-831-7133 Fax: 800-284-4151
www.pentairpool.com

MegaTherm

®

Part Numbers

Descriptions

Cupronickel alloy heat exchanger models are available. Contact the factory for part numbers.

MT0500IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT0600IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT0715IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT0850IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT0999IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT1010IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT1200IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT1430IN09C1PC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT1670IN09CBPC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT1825N09CBPC

Indoor, Spark Ignition, On-Off, Pump Mtd., Cl-Cu HX, Std. Unit, Nat. Gas

MT2000IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT2450IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT3050IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT3500IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT4050IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT4500IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT5000IN18CCAC

Indoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas

MT2200EN18CCAC Outdoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas
MT2800EN18CCAC Outdoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas
MT3200EN18CCAC Outdoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas
MT3600EN18CCAC Outdoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas
MT4000EN18CCAC Outdoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas
MT4500EN18CCAC Outdoor, Spark Ignition, Less Pump, Cl-Cu HX, Std. Unit, Nat. Gas
MT2200EN18CCAN Outdoor, Spark Ignition, Less Pump, Cl-Cu-Ni HX, Std. Unit, Nat. Gas
MT2800EN18CCAN Outdoor, Spark Ignition, Less Pump, Cl-Cu-Ni HX, Std. Unit, Nat. Gas
MT3200EN18CCAN Outdoor, Spark Ignition, Less Pump, Cl-Cu-Ni HX, Std. Unit, Nat. Gas
MT3600EN18CCAN Outdoor, Spark Ignition, Less Pump, Cl-Cu-Ni HX, Std. Unit, Nat. Gas
MT4000EN18CCAN Outdoor, Spark Ignition, Less Pump, Cl-Cu-Ni HX, Std. Unit, Nat. Gas
MT4500EN18CCAN Outdoor, Spark Ignition, Less Pump, Cl-Cu-Ni HX, Std. Unit, Nat. Gas