DIMENSIONAL AND SIzINg DAtA
For Indoor Pools Model I
1. Calculate the surface area of the pool in square feet.
2. Refer to the selection chart for either an indoor or outdoor heater.
3. Find the closest square footage in the 10° F (6° C) Temperature Difference column, and the heater models which correspond to it. For normal conditions,
Pentair recommends using the 10° F Temperature Difference columns; this will provide a temperature increase of approximately 6° F per 24 hour period.
10° F
6° C
15° F
8° C
20° F
11° C 25° F
14° C
30° F
17° C 35° F
19° C
40° F 22° C 45° F
25° C
50° F 28° C
Model
Surface Area of Pools (Sq. Ft.)
500 I
3900
362
2600
242
1950
181
1560
145
1300
121
1115
104
975
91
870
81
780
72
600 I
4680
435
3120
290
2340
217
1870
174
1560
145
1340
124
1170
109
1040
97
935
87
715 I
5580
518
3720
346
2790
259
2230
207
1860
173
1595
148
1395
130
1240
115
1115
104
850 I
6630
616
4420
411
3315
308
2650
246
2210
205
1895
176
1660
154
1475
137
1325
123
1010 I
7880
732
5250
488
3940
366
3150
293
2625
244
2259
210
1970
183
1750
163
1575
146
1200 I
9360
870
6240
580
4680
435
3745
348
3120
290
2675
249
2340
217
2080
193
1870
174
1430 I
11155 1036
7435
691
5580
518
4460
414
3720
346
3190
296
2790
259
2480
230
2230
207
1670 I
13025 1210
8685
807
6515
605
5210
484
4340
403
3720
346
3260
303
2895
269
2605
242
1825 I
14235 1322
9490
882
7120
661
5695
528
4745
441
4070
378
3560
331
3165
294
2850
265
2000 I
16400 1524
10935 1016
8200
819
6560
609
5465
508
4685
435
4100
381
3645
339
3280
305
2450 I
20090 1866
13395 1244 10045
933
8035
746
6695
622
5740
533
5025
467
4465
415
4020
373
3050 I
25010 2323
16675 1549 12505
1162 10000
929
8335
744
7145
664
6255
581
5560
517
5000
465
3500 I
28700 2666
19135 1778 14350
1333 11480 1066
9565
889
8200
764
7175
667
6380
593
5740
533
4050 I
33210 3085
22140 2057 16605
1543 13285 1234 11070 1028
9490
882
8300
771
7380
686
6640
617
4500 I
36900 3428
24600 2285 18450
1714 14760 1371 12300 1143 10545
980
9225
857
8200
762
7380
686
5000 I
41000 3809
27335 2539 20500
1904 16400 1524 13665 1269 11715 1088 10250
952
9110
846
8200
762
temperature Difference
Indoor
Sizes 500 –1825
Indoor
Sizes 2000 – 5000
Dimensional Data
Indoor Input
1
Output
1
- inches NPt - inches Dimensions
2
- inches cm Weight
3
Size MBtU/h kw MBtU/h kw Nat
LP NPt A B C V lbs. kg
500 I 500 147 405 119 1
3
⁄
4
2
1
⁄
2
33
3
⁄
4
86 45
1
⁄
4
115 23
3
⁄
4
60 10 25 808 367
600 I 600 176 486 143 1
3
⁄
4
2
1
⁄
2
38
3
⁄
4
98 50
1
⁄
4
128 22
3
⁄
4
58 12 30 819 372
715 I 715 210 579 170 1
3
⁄
4
2
1
⁄
2
44
1
⁄
4
112 55
3
⁄
4
142 22
3
⁄
4
58 12 30 873 396
850 I 850 249 689 202 1
3
⁄
4
2
1
⁄
2
50
3
⁄
4
129 62
1
⁄
4
158 21
3
⁄
4
55 14 36 945 429
1010 I 1010 296 818 240 1
1
⁄
4
1
2
1
⁄
2
58 147 69
1
⁄
2
177 20
3
⁄
4
53 16 41 1041 473
1200 I 1200 352 972 285 1
1
⁄
4
1
2
1
⁄
2
66
1
⁄
4
168 77
3
⁄
4
197 20
3
⁄
4
53 16 41 1199 544
1430 I 1430 419 1158 339 1
1
⁄
4
1
1
⁄
4
2
1
⁄
2
76 193 87
1
⁄
2
222 19
3
⁄
4
50 18 46 1280 581
1670 I 1670 489 1353 396 1
1
⁄
2
1
1
⁄
4
2
1
⁄
2
85
1
⁄
2
217 97 246 19
3
⁄
4
50 18 46 1445 656
1825 I 1825 535 1478 433 1
1
⁄
2
1
1
⁄
4
2
1
⁄
2
92
1
⁄
2
235 103
3
⁄
4
264 19
3
⁄
4
50 18 46 1570 713
2000 I 2000 586 1639 480 1
1
⁄
2
1
1
⁄
4
4
55
1
⁄
2
141 73 185 24
1
⁄
2
62 22 56 1950 885
2450 I 2450 718 2009 589 1
1
⁄
2
1
1
⁄
2
4
65
1
⁄
2
166 83 211 24
1
⁄
2
62 24 61 2100 913
3050 I 3050 894 2501 733 2 1
1
⁄
2
4
78 198 95
1
⁄
2
243 24
1
⁄
2
62 26 66 2250 1022
3500 I 3500 1025 2870 841 2 1
1
⁄
2
4
88 224 105
1
⁄
2
268 24
1
⁄
2
62 28 71 2510 1140
4050 I 4050 1186 3321 973 2
2
4
100
1
⁄
2
255 118 300 24
1
⁄
2
62 30 76 2750 1249
4500 I 4500 1318 3690 1081 2
1
⁄
2
2
4
110
1
⁄
2
281 128 325 24
1
⁄
2
62 32 81 2900 1317
5000 I 5000 1465 4100 1201 2
1
⁄
2
2
4
123 312 140
1
⁄
2
357 24
1
⁄
2
62 34 86 3200 1453
gas Conn. Size
2
Water Conn. Size
2
NOTES: 1. Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.
2. Dimensions are nominal.
3. Integral pump included on sizes 500-1825.