Operation – Lincoln Electric FLEXTEC 450 CE User Manual

Page 23

background image

B-6

OPERATION

B-6

FLEXTEC™ 450 CE

Amperage Display Meter

• Prior to STICK or TIG operation (current flow), the

meter displays preset current value.

• Prior to CV operation, the meter displays four dash-

es indicating non-presettable AMPS.

• During welding, this meter displays actual average

amps.

• After welding, the meter holds the actual current

value for 5 seconds. The displays blink indicating
that the machine is in the "hold" period.

•Output adjustment while in the "hold" period results

in the "prior to operation" characteristics

Weld Terminals On/Remote Toggle Switch

• This switch determines the trigger location.
• When set to the “ON” position, the weld terminals

are at OCV (open circuit voltage) and ready to weld.

• When set to the “REMOTE” position, output is

enabled through a remote trigger.

Control - Local/Remote Toggle Switch

• Set the switch to “Local” to control output at the

machine by the Output Control dial.

• Set the switch to “REMOTE” to control output via a

remote device (K857 hand amptrol or K870 foot
amptrol) connected to the 6-pin remote connector
or a wire feeder connected to the 14-pin connector.

Thermal Light

• This status light indicates when the power source

has been driven into thermal overload. If the output
terminals were "ON", the output will be turned back
on once the unit cools down to an acceptable tem-
perature level. If the unit was operating in the
"REMOTE" mode, the trigger will need to be
opened before or after the thermal has cleared and
closed after the machine has cooled down to an
acceptable temperature to establish output.

VRD™ (VOLTAGE REDUCTION DEVICE)
INDICATOR LIGHT

There are 2 indicator lights on the case front of the
Flextec™ 450 CE above the Voltage LCD Display to
indicate the status of VRD operation.

• A green light indicates the OCV (open circuit volt-

age) is less than 35V.

• A red light indicates the OCV is at or above 35V.

VRD™ is enabled via a dip switch on the Control
P.C. board (see Figure B.3). This switch must be in
the “On” position for the VRD™ function to be active
and the lights to be enabled. If VRD™ is enabled,
both lights will illuminate for 5 seconds at power up.

For each weld mode, the VRD™ lights function as
shown in Table B.1:

VRD Indicator Lights

TABLE B.1

FIGURE B.3

* It is normal for the lights to alternate between colors while welding.

Mode

VRD “ON”

Green (OCV reduced)
Green or Red (depends on weld voltage)*
Red (OCV Not Reduced)

Weld Terminals ʻONʼ
Red (OCV Not Reduced)
Weld Terminals Remotely Controlled
Gun Trigger Closed
Green (NO OCV)
Weld Terminals Remotely Controlled
Gun Trigger Open
Green or Red (depends on weld voltage)*

CC-MMAW
CC-GTAW
CV-GAS
C V-Innershield

OCV
While welding
OCV

While welding

VRD “OFF”

No lights are

active

Dip Switch Location on Control P.C. Board

Location of Control P.C. Board

ON

1 2 3 4 5 6 7 8

OFF

VRD Mode Setting
- Switch #5 in the “ON” Position