1
At least 31 square inches (200cm
2
)
1
2
1 1/2”
(38
mm)
2
0
3/4
”
(5
27
m
m
)
Figure 19
2
1
5
1/2"
(13 mm)
24"
(609,6 mm)
3-11/16"
(93,7 mm)
Figure 20
The following ventilation cross-section
and distances must be observed:
- There must be a ventilation space of
at least 31 square inches (200 cm²)
per appliance in the cabinet plinth
and under the cabinet top panel.
- The depth of the ventilation duct at
the rear of the cabinet must be at
least 1-1/2" (38 mm).
Alternatively:
1. For built-in appliances without ven-
tilation grilles and only with an instal-
lation frame, ventilation must take place
through the ventilation duct at the rear
of the cabinet.
Built-in appliances with an installation
frame:
•
Figure 19:
- Screw the complete installation
frame (2) to the appliance.
2. Built-in appliances with a wooden
ventilation grille:
Figure 20: Cut out the wooden trim
for use as a ventilation grille using the
enclosed template.
- The required ventilation cross-sec-
tion must be at least 31 square
inches (200 cm²) when a single
appliance is installed, which cor-
responds to template “small” (If you
install two appliances side-by-side,
the cross-section must be at least
62 square inches, (400 cm²), which
corresponds to template “double-
size;” for more information see “Side-
by-Side Installation”).
•
Remove the attachment bracket (2)
from the installation frame and screw it
to the appliance (1) from underneath.
Place the wooden ventilation grille (5)
on the appliance, align it in the center
and secure it from the rear using the
attachment bracket (2).