beautypg.com

Langley/Empire RH-25-6 User Manual

Page 15

background image

Page 15

12821-6-0406

Code, CSA C22.1, if an external electrical source is utilized. This

appliance is equipped with a three-prong [grounding] plug for

your protection against shock hazard and should be plugged

directly into a properly grounded three-prong receptacle. Do

not cut or remove the grounding prong from this plug. For an

ungrounded receptacle, an adapter, which has two prongs and a

wire for grounding, can be purchased, plugged into the ungrounded

receptacle and its wire connected to the receptacle mounting screws.

With this wire completing the ground, the appliance cord plug can

be plugged into the adapter and be electrically grounded.

CAUTION: Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper and

dangerous operation. Verify proper operation after servicing.

WARNING:

Unplugging of blower accessory will not stop the heater

from cycling. To shut heater off:

1. Turn temperature dial or thermostat to lowest setting.

2. Turn knob on gas control to “OFF”, depressing slightly.

Do not force.

Cleaning

The blower wheel will collect lint and could require cleaning once

a year. If the air output decreases or the noise level increases, it

indicates a dirty wheel. Complete removal of the wheel and scrub-

bing it with a brush under flowing water is recommended.
Oiling

The blower motor has an oil hole located on each end of the motor.

Use #20 motor oil only. It is best to oil the motor several times

during the heating season using 2 or 3 drops each time. If the mo-

tor fails to start and hums, it could be a tight bearing due to lack of

oil. This may be corrected by pouring kerosene in the oil holes,

allowing to stand for a few hours and then oiling properly.

Parts List

Index

No.

Part

No.

Description

1

R-2090

Motor

2

632016

Motor Cushion

3

RH-036

Motor Support

4

642030

Blower Wheel

5

RH-710

Blower Housing Assembly

6

9120106

Fan Control Switch

7

872087

Heyco Bushing

8

DV-806

Switch Box

9

DV-807

Switch Box Cover

10

R-2091

Wire Assembly 19" (483mm)

11

8720161

Heyco Bushing

12

R-2099

Cord Set 72" (183cm)

This manual is related to the following products: