beautypg.com

Operation – Lincoln Electric INVERTEC POWER WAVE IM542-D User Manual

Page 26

background image

1. LCD DISPLAY WINDOW: Power up the machine

with this overlay in place. When the Power Wave
is turned on, the following message appears in the
display window for a few seconds:

LINCOLN ELECTRIC

Version X.X

This display is followed by:

OVERLAY ID

NUMBER = 10

This message is then replaced by the following
message:

SELECT A MEMORY

LOCATION

2. MEMORY RECALL KEYS: The following four

memory pairs are available on this overlay:
Memory 1 and Memory 2
Memory 3 and Memory 4
Memory 5 and Memory 6
Memory 7 and Memory 8

Select a memory location PAIR for the two desired
welding procedures by pressing either of the two
corresponding MEMORY RECALL NUMBER keys.

If no procedure was saved to one of the memory
pair locations, the following message appears:

MEMORY LOCATION

# IS EMPTY

In this case select another memory pair.

Set the dual procedure switch or gun trigger to the
position for PROCEDURE A or PROCEDURE B.
Position A activates the welding procedure from
the odd numbered memory locations (1, 3, 5 or 7).
Position B activates the welding procedure from
the corresponding even numbered memory loca-
tions (2, 4, 6 or 8). For example, if memory loca-
tion 3 was selected, Position A activates the
procedure from memory location 3; Position B
activates the procedure from memory location
4.

When a pair of welding procedures are recalled
from memory, the display window will show the
procedure description, wire feed speed, and the
preset voltage or arc length trim of the LAST pro-
cedure welded with.

With this overlay in place, the wire feed speed and
the preset voltage or arc length trim can be
changed from the robot controller. The new values
will replace the previous values and become a per-
manent part of the procedure.

If limits have been set on the wire feed speed, volt-
age or arc length trim of the selected procedure,
these limits will be active when this overlay is in
place. They cannot be overridden from this over-
lay.

OPERATION

B-10

B-10

POWER WAVE 450

ROBOTIC INTERFACE WELD FROM MEMORY, DUAL PROCEDURE OVERLAY

The Weld From Memory, Dual Procedure Overlay lets an operator recall and use any welding procedure stored in
one of eight memory locations. See Figure B.5.

FIGURE B.5 – ROBOTIC INTERFACE WELD FROM MEMORY, DUAL PROCEDURE OVERLAY

1

6

2

3

4

5

7

PANEL-10 ROBOTIC INTERFACE (WELD FROM MEMORY, DUAL PROCEDURE)

FOR ROBOTIC APPLICATIONS ONLY

L9169-10

ROBOTIC INTERFACE

TOUCH SENSING

1 LCD DISPLAY WINDOW
2 MEMORY RECALL KEYS
3 PROGRAM LIST
4 DISPLAY RECALL KEY
5 HIGH TEMPERATURE LIGHT
6 MEMORY LIGHTS
7 TOUCH SENSING LIGHT