Lot series, Va s, Ingle – Lightolier LOT Series User Manual
Page 2: Hase

LOT Series
1.5-4.2
K
VA S
INGLE
P
HASE
UPS
Page 2 of 2
Philips Lightolier
e: [email protected]
t: (508)
679-8131
w: www.lightolier.com
LOT Series - 1.5-4.2 September 7, 2011
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2011. All rights reserved.
Job Information
Type:
Ordering Information
On Bus w/ Optional
Distribution
Optional Off/
Timed Off Bus w/
Distribution
DC
Fuse
Battery
Pack
Input
Circuit
Breaker
Inverter
Fuse
AC
Input
SS
System Rating (kW/kVA)
Input Volt. (V) : Input Curr. (A)
Output Volt. : Output Current*
OCB Pole Spaces Available
Without Trip Alarm
With Trip Alarm
Heat Rejection (btu/hr)
Weight (lbs)
Electronics
90 Min Battery
20 Min Battery
10 Min Battery
1.5
120 : 22.1
120/240 : N/A
277 : 9.8
120/208 : N/A
120 : 12.5
120/240 : N/A
277 : 5.4
120/208 : N/A
120/277 : 12.5/5.4
20
10
716
650
445
90
60
System Input/Output Ratings
SS
Bypass
Output
Hardwired
(Standard)
P
F
C
Series
LOT = Single
Phase UPS
System for
Emergency
Lighting
Applications
A = 120 V
G = 120/240 V
J = 277 V
L = 120/208 V
Input Voltage
Qty Circuit
Breakers
00X = Hardwire
01X = 1 OCB
02X = 2 OCB
03X = 3 OCB
04X = 4 OCB
.
.
20X = 20 OCB
01A = 1 OCBA
02A = 2 OCBA
03A = 3 OCBA
.
.
10A = 10 OCBA
(max. pole spaces 20)
LOT
Unit Size
1.5 = 1.5 kVA
2.2 = 2.2 kVA
3.0 = 3.0 kVA
3.5 = 3.5 kVA
4.2 = 4.2 kVA
Battery Time
S = 90 Min
X = 10 Min
Y = 20 Min
# Nol Circuit
Breakers
A = 1
B = 2
C = 3
D = 4
E = 5
F = 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
T = 20
Z = No Nol
Hardwired
System One-Line Diagram
A = 120 V
G = 120/240 V
J = 277 V
L = 120/208 V
Y = 120/277 V
Output Voltage
Nol
0 = None
1 = Yes
T = Nol w/
TDT
Breakers On
2nd Voltage
00 = 2nd
Voltage
Hardwire
or No 2nd
Voltage
01
02
03
.
.
19
Nol Voltage
1 = First
2 = Second
3 = Both
0 = No Nol
Qty Nol 2nd
Voltage
A = 1
B = 2
C = 3
D = 4
E = 5
F = 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
Z = No Nol
2.2
120 : 26.7
120/240 : N/A
277 : 11.9
120/208 : N/A
120 : 18.3
120/240 : N/A
277 : 7.9
120/208 : N/A
120/277 : 18.3/7.9
20
10
1050
650
445
195
90
3.0
120 : 39.4
120/240 : 19.1
277 : 17.1
120/208 : 22.1
120 : 25.0
120/240 : 25/12.5
277 : 10.8
120/208 : 25/14.4
120/277 : 25/10.8
20
10
1432
640
610
330
195
3.5
120 : 45.0
120/240 : 21.8
277 : 19.5
120/208 : 25.2
120 : 29.2
120/240 : 29.2/14.6
277 : 12.6
120/208 : 29.2/16.8
120/277 : 29.2/12.6
20
10
1670
640
610
330
195
4.2
120 : 47.0
120/240 : 23.5
277 : 20.3
120/208 : 27.0
120 : 35.0
120/240 : 35/17.5
277 : 15.2
120/208 : 35/20.2
120/277 : 35/15.2
20
10
2005
840
760
350
230
Rectifier
Inverter
Output
Circuit
Breaker
* Multi-voltage total loads not to exceed system rating.