WATERPIK TECHNOLOGIES INC.

9.

Once the temperature is within the correct range,
safety wire the handle of the manual bypass valve
in place and tag the valve to prevent change in the
water flow.

SECTION 3.
Operating Instructions

3A. General Information

With any new pool or spa installation, operate the

filter pump with the heater off long enough to com-
pletely clean the water. This will remove any installation
residue from the water. Clean the filter at the end of this
operation before starting the heater. When raising the
temperature of a cold pool, remove all time clock
settings. This lets the filter system and heater operate
continuously until the water reaches the temperature
setting on the temperature control. When that happens,
the heater will automatically shut off, but the filter pump
will keep running.

Caution

Do not use this heater if any part has been

under water. Immediately call a qualified

service technician to inspect the heater and

replace any part of the control system and any

gas control which has been under water.

Attention

N'utilisez pas cet appareil s'il a été plongé

dans l'eau, même partiellement. Faites

inspecter l'appareil par un technicien qualifié

et remplacez toute partie du système de

contrôle et toute commande qui ont été

plongés dans l'eau.

Caution

Should overheating occur or the gas supply

fail to shut off, turn off the manual gas control

valve to the heater.

Attention

En cas de surchauffe ou si l'alimentation en

gaz ne s'arrête pas, fermez manuellement le

robinet d'arrêt de l'admission de gaz.

Caution

Keep all objects off the top of the heater.

Blocking air flow could damage the heater,

and may void the warranty.

WARNING

Vent pipes, drafthoods, and heater tops get

hot! These surfaces can cause serious burns.

Do not touch these surfaces while the heater

is in operation. Adding a vent cap reduces the

temperature on the top.

WARNING

For your safety, when starting the heater, keep

your head and face well away from the lower

firebox opening to prevent any risk of personal

injury.

3B. Lighting and Shutdown Procedures

NOTE: If your LP tank runs out of fuel, turn off
gas at the heater. After the tank is refilled, the
heater must be relit following the instructions
found on the inside of the heater. DO NOT
attempt repairs on the gas control or heater.
Tampering is dangerous and voids all warranties.

3B-1. Model LD (see Page 17).

3B-2. Model LG (see Page 18).

3C. Setting the Temperature Control

The temperature control (see Figure 18) is

calibrated at the factory and covers a range from
approximately 70°F to 104°F (21°C to 40°C). Use an
accurate pool thermometer to determine the best water
temperature for your uses.

The Laars Lite 2 model LD has dual temperature

controls, which allows two different temperature
settings, selected by the rotary switch in the middle of
the panel. One control can be set for normal use and
the other for standby; or one can be set for pool and
the other for a spa. Placing the rotary switch in the
middle turns off the heater (see Figure 18). The model
LG has only a single control and is set similarly to the
LD above.

IMPORTANT: The temperature controls cannot

be calibrated in the field. If the control is faulty, shut
down the heater and have a qualified service technician
replace the control. DO NOT use the thermostat switch
to completely shut down the heater.