Knight, Xl boiler dimensions and specifications, Optional equipment – Lochinvar KNIGHT XL KBN600 User Manual

Page 6: Firing codes, Standard features, Smart system features

background image

>

Low Voltage Terminal Strip

>

24 VAC Auxiliary Device Relay

>

Auxiliary Proving Switch Contacts

>

Flow Switch Contacts

>

Alarm on Any Failure Contacts

>

Runtime Contacts

>

DHW Thermostat Contacts

>

Room Thermostat Contacts

>

System Sensor Contacts

>

DHW Tank Sensor Contacts

>

Outdoor Air Sensor Contacts

>

Cascade Contacts

>

0-10 VDC BMS External Control Contact

Optional Equipment

>

Alarm Bell on Any Failure

>

Condensate Neutralization Kit

>

High & Low Gas Pressure Switches w/ Manual

Reset (KB500-KB800)

>

Low Water Cutoff w/Manual Reset & Test

>

SMART SYSTEM PC Software

>

Stainless Steel Vent Kits (KB700-KB800)

>

Multi-Stack Frame

Firing Codes

>

M9 Standard

Construction

>

M7 California

Code

>

M13

CSD1 / FM / GE Gap (KB500-KB800)

Standard Features

>

Up to 94.6% Thermal Efficiency

>

Modulating Burner with 5:1 Turndown

>

Direct-Spark Ignition

>

Low NOx Operation

>

Sealed Combustion

>

Low Gas Pressure Operation

>

Vertical & Horizontal Direct-Vent

>

Category IV venting up to 100 feet

>

PVC, CPVC or AL29-4C Venting up to 100 Feet

>

Factory Supplied Sidewall Vent Termination

>

ASME Stainless Steel Heat Exchanger

>

ASME Certified, ”H” Stamped

>

Gasketless Heat Exchanger

>

160 psi Working Pressure

>

Highly efficient, condensing design

>

On/Off Switch

>

Adjustable High Limit w/ Manual Reset

>

Flow Switch

>

Inlet & Outlet Temperature Sensors

>

Flue Temperature Sensor

>

Low Air Pressure Switch

>

50 psi ASME Relief Valve

>

Temperature & Pressure Gauge

>

Adjustable Leveling Legs

>

Condensate Trap

>

Zero Clearances to Combustible Material

>

10 Year Limited Warranty

(See Warranty for Details)

Smart System Features

>

SMART SYSTEM Digital Operating Control

>

2 line, 16 Character Display

>

Dual Level Password Security

>

Domestic Hot Water Prioritization

>

Built in Cascading Sequencer for up to 8 Boilers

>

Building Management System Integration

with 0-10 VDC Input

>

Outdoor Reset Control with Outdoor Air Sensor

>

Low Water Flow Safety Control & Indication

>

Inlet & Outlet Temperature Readout

>

Freeze Protection

>

Service Reminder

>

Time Clock

>

Data Logging

>

Hours Running, Space Heating

>

Hours Running, Domestic Hot Water

>

Ignition Attempts

>

Last 10 Lockouts

>

Programmable System Efficiency Optimizers

>

Night Setback

>

Anti-Cycling

>

Outdoor Air Reset Curve

>

Ramp Delay

>

Boost Temperature & Time

>

Three Pump Control

>

System Pump

>

Boiler Pump

>

Domestic Hot Water Pump

>

High Voltage Terminal Strip

>

120 VAC / 50-60 Hertz / 1 Phase Power Supply

>

Three sets of Pump Contacts with Pump Relays

KBX-03

(Replaces KBX-02 6/08)

5M-4/09-Printed in U.S.A.

3 0 0 M a d d o x S i m p s o n P a r k w a y, L e b a n o n, T N 3 7 0 9 0 | 6 1 5 - 8 8 9 - 8 9 0 0 | f a x : 6 1 5 - 5 4 7 - 1 0 0 0 | w w w . l o c h i n v a r .c o m

Knight

®

XL Boiler Dimensions and Specifications

Model Number Guide

KB N 700 M13

Model

Firing Controls

Natural Gas

Btu/hr Input

Input

Net

Model

Min

Max

Thermal

Output I=B=R

Number MBH MBH Efficiency

MBH

MBH

KBN399 80 399 93.3%

372

324

KBN500 100 500 93.3%

467

406

KBN600 120 600 94.6%

567

493

KBN700 140 700 94.3%

660

574

KBN800 160 800 94.0%

752

654

A

B

C

D E

F G H

I

J

K Gas

Water Air Vent

Shipping

Conn. Conn. Inlet Size Wt. (lbs.)

42-1/2”

15-1/2”

27-3/4” 3-3/4” 20-3/4” 21”

14” 34”

34”

2”

18-3/4”

1” 1-1/2” 4”

4”

280

42-1/2”

15-1/2”

31-1/4” 3-3/4” 25-1/2” 21” 14” 32-1/2” 36”

2”

18”

1” 1-1/2” 4”

4”

310

42-1/2”

15-1/2”

36-1/4” 3-3/4” 25”

21” 14” 36”

32-3/4” 5-1/2” 19-1/2”

1”

2”

4”

4”

340

42-1/2”

15-1/2”

40-1/4” 3-3/4” 29”

23” 17” 36”

32-3/4” 3-1/4” 23-1/2”

1”

2”

4”

6”

370

42-1/2”

15-1/2”

45-1/4” 3-3/4” 33-1/4” 23”

17” 36”

32-3/4” 3-1/4” 27-3/4”

1”

2”

4”

6”

405

Notes: Change ‘N’ to ‘L’ for L.P. Gas Model. No deration on L.P. models. Performance data based on manufacturer test results. 120 VAC /15 AMP circuit required.

All dimensions shown in inches.

Knight XL Heating Boiler

Dimensions and Specifications

Knight XL Boiler,

Natural Gas,

700,000 Btu/hr input,

M13 firing controls

>

Mo

>

Di

>

Lo

>

Se

>

Lo

>

Ver

>

Ca

>

PV

>

Fa

>

ASM

>

AS

>

Ga

>

16

>

Hi

>

On/

>

Adj

>

Flow

>

Inle

>

Flue

>

Low

>

50

>

Tem

>

Adj

>

Con

>

Zer

>

10

(Se

KBX-0

3 0 0

Input

Net

nput

et

Model Min

Max Thermal

Output I=B=R

odel

a

e al

Output

Number MBH

MBH Efficiency

MBH

MBH

A

B C D

E F G H I J

A

B

C

D

E

F

G

H

I

J

Knight XL Heating Boiler

Dimensions and Specifications

LEFT SIDE

FRONT

BACK

8"

39-1/2"

13-3/4"

18-3/4"

H

K

D

G

F

E

C

9"

A

1-1/4"

1/4" -

ADJUSTABLE

AIR INLET

FLUE

LOW VOLTAGE

ELECTRICAL

CONNECTIONS

GAS

INLET

OUTLET

HEAT

EXCHANGER

DRAIN

3/4" NPT

CONDENSATE

DRAIN

FLUE

B

I

J

HIGH VOLTAGE

ELECTRICAL

CONNECTIONS

38-3/4"

3-1/2"

Patent # 7,506,617

This manual is related to the following products: