Power-fin, Water heater product summary – Lochinvar Power Fin PF-1701 (M9) User Manual
Page 2
PF-0502 (F9)
PF-0752 (F9)
PF-1002 (F9)
PF-1302 (F9) PF-1501 (B9) PF-1701 (B9) PF-2001 (B9)
WATER
GALLON CAPACITY
3.5
4.0
4.5
5.0
5.5
5.8
6.0
HEATING SURFACE (SQ. FT.)
58.7
88.2
116.0
149.2
156.8
177.8
209.4
WATER CONNECTIONS
2-1/2”
2-1/2”
2-1/2”
2-1/2”
2-1/2”
2-1/2”
2-1/2”
DRAIN
2 @ 3/4”
2 @ 3/4”
2 @ 3/4”
2 @ 3/4”
2 @ 3/4”
2 @ 3/4”
2 @ 3/4”
MAX. WATER FLOW RATE (GPM)
75
75
75
75
90
90
90
HEAD LOSS (FT. OF HD.)
7.2
7.5
7.8
9.5
10.5
11.8
12.4
MAX. WORKING PRESSURE (PSI)
160
160
160
160
160
160
160
MAX. WATER HARDNESS (GRAINS)
25
25
25
25
25
25
25
GPH @ 70°F RISE
736
1,104
1,472
1,913
2,205
2,501
2,940
GPH @ 100°F RISE
515
773
1,030
1,323
1,527
1,731
2,036
GPH @ 140°F RISE
368
552
736
957
1,075
1,219
1,433
# OF RELIEF VALVES
1
1
1
1
1
1
1
RELIEF VALVE SIZE
3/4”
3/4”
3/4”
3/4”
1”
1”
1”
RELIEF VALVE RATING (MBH)
1,912
1,912
1,912
1,912
2,155
2,155
2,155
RELIEF VALVE PRESSURE RATING (PSI)
150
150
150
150
150
150
150
RELIEF VALVE TEMPERATURE RATING (°F)
210
210
210
210
210
210
210
GAS
INLET CONNECTION
1”
1-1/4”
1-1/4”
1-1/4”
1-1/2”
1-1/2”
1-1/2”
MAX. INLET PRESSURE, NAT
10.5” w.c.
10.5” w.c.
10.5” w.c.
10.5” w.c.
14.0” w.c.
14.0” w.c.
14.0” w.c.
MIN. INLET PRESSURE, NAT
4.2” w.c.
4.2” w.c.
4.2” w.c.
4.2” w.c.
4.0” w.c.
4.0” w.c.
4.0” w.c.
MANIFOLD PRESSURE, NAT
3.2” w.c.
3.2” w.c.
3.2” w.c.
3.2” w.c.
-5.3” w.c.
-6.3” w.c.
-3.9” w.c.
MAX. INLET PRESSURE, LP
13.0” w.c.
13.0” w.c.
13.0” w.c.
13.0” w.c.
14.0” w.c.
14.0” w.c.
14.0” w.c.
MIN. INLET PRESSURE, LP
11.0” w.c.
11.0” w.c.
11.0” w.c.
11.0” w.c.
8.0” w.c.
8.0” w.c.
8.0” w.c.
MANIFOLD PRESSURE, LP
10.0” w.c.
10.0” w.c.
10.0” w.c.
10.0” w.c.
-3.4” w.c.
-3.8” w.c.
-2.1” w.c.
BTU/HR INPUT
500,000
750,000
1,000,000
1,300,000
1,500,000
1,700,000
2,000,000
ELECTRICAL
VOLTAGE/HEATER
120
120
120
120
120
120
120
VOLTAGE/PUMP
120
120
120
120
120
120
120
VOLTAGE/CONTROL
24
24
24
24
24
24
24
TOTAL AMPS W/PUMP
15.5
15.5
15.5
15.5
15.3
15.3
15.3
# OF ELECTRICAL CONNECTIONS
1
1
1
1
1
1
1
DIMENSIONS
HEIGHT
44-1/2”
52-1/4”
59-1/4”
67-3/4”
65-1/2”
70”
76-3/4”
WIDTH
23-1/4”
23-1/4”
23-1/4”
23-1/4”
27-1/4”
27-1/4”
27-1/4”
DEPTH (INCLUDES PUMP)
42-3/4”
42-3/4”
42-3/4”
42-3/4”
56”
56”
56”
SERVICE CLEARANCES
FRONT
24”
24”
24”
24”
24”
24”
24”
BACK (PIPING)
24”
24”
24”
24”
24”
24”
24”
RIGHT SIDE
0”
0”
0”
0”
0”
0”
0”
LEFT SIDE
0”
0”
0”
0”
0”
0”
0”
TOP
24”
24”
24”
24”
24”
24”
24”
VENTING
SIZE
7”
9”
10”
12”
12”
14”
14”
VENT CATEGORY
I
I
I
I
I
I
I
VENT MATERIAL
B-VENT
B-VENT
B-VENT
B-VENT
B-VENT
B-VENT
B-VENT
MAXIMUM DRAFT
-0.08” w.c.
-0.08” w.c.
-0.08” w.c.
-0.08” w.c.
-0.08” w.c.
-0.08” w.c.
-0.08” w.c.
MINIMUM DRAFT
-0.02” w.c.
-0.02” w.c.
-0.02” w.c.
-0.02” w.c.
-0.02” w.c.
-0.02” w.c.
-0.02” w.c.
PFX-PS-02 (Replaces PFX-PS-01 10/07)
11/07-Printed in U.S.A.
POWER-FIN
®
WATER HEATER PRODUCT SUMMARY
(PF) 500,000 - 2,000,000 BTU/HR
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com