beautypg.com

Adjustment instructions, Safety precautions, Test equipment required – LG CT-25/29M60VE/VQ User Manual

Page 9: Dvco adjustment, Focus adjustment, Screen voltage & white balance adjustment

background image

- 9 -

1. Safety Precautions

1. It is safe to adjust after using insulating transformer between

the power supply line and chassis input to prevent the risk of
electric shock and protect the instrument.

2. Never disconnect leads while the TV receiver is on.
3. Don't short any portion of circuits while power is on.
4. The adjustment must be done by the correct appliances.
5. Unless otherwise noted, set the line voltage to 230Vac

!

10%,

50Hz.

6. The adjustment of TVshould be performed after warming up

for 15 minutes.

2. Test Equipment required

1. RF signal generator (with pattern generator)
2. DC Power Supply
3. Multimeter (volt meter)
4. Oscilloscope
5. Color analyzer

3.DVCO Adjustment

1) This is for adjustment of VCT38XX,crystal oscillator

frequency after receiving a company Digital
pattern.(PAL:EU05CH,NTSC:13CH)

2)

When entering adjustment mode by pressing IN-START
button,DVCO adjustment is operating automatically.
(T/X doesn’t operating occassionally during DVCO
adjustment.)

4. Focus Adjustment

4-1. Preparation for Adjustment

Tune the TV set to receive a digital pattern.

4-2. Adjustment Method

1) Single Focus CPT

Adjust the upper Focus volume of FBT for the best focus of

horizontal line A,vertical line B.

2) Double Focus CPT

1) Adjust the lower Focus volume of FBT for the best focus of

vertical line B.

2) Adjust the upper Focus volume of FBT for the best focus of

area A.

3) Repeat above step 1) and 2) for the best overall focus.

5. Screen Voltage & White Balance Adjustment

5-1. Adjustment of screen manually

(Using ADJ.Remote Control)

1) Receive the PAL or SECAM(NTSC) signal into RF mode

regardless of channel.

2) If you press the “ADJ”button in LINE SVC mode(IN-START

button),the LINE SVC mode changes to screen adjustment
mode.

3) Turn the Sreen Volume of FBT to change luminance of

White signal center as shown below.(Deviation

!

1FL)

4) Press the EXIT button (Like TV/AV) to exit SVC mode.

5-2. Adjustment of white balance manually(LIne-SVC 1)

1) Tune the TV set to receive an 100% white pattern.
2) Adjust LOW LIght status of CUT R,CUT B at CUT G:50.
3) Adjust HIGH LIght status of WDR R,WDR B at WDR G:380.
4) Repeat above step 2) and 3) for the best condition each

status of High Light and Low Light.

NOTE : When adjusting white balance automatically,connect the

adjustment JIG in SVC mode.(When pressing IN-
START,MUTE button on remote control for adjustment
orderly,it changes to SVC mode and screen displays
SVC.)

Luminance(Manual)

6

!

1FL

8

!

1FL

5

!

1FL

6

!

1FL

8

!

1FL

CPT & INCH

29” FLAT

25” FLAT

29” NORMAL

25” NORMAL

28” NORMAL

Note

Single Focus

ADJUSTMENT INSTRUCTIONS

b

A

B

Fig. 1

Menu

X

Y

Color Temperature

288

295

9000

o

K

268

273

13000

o

K

EU

N-EU

Menu

CUR R

CUR G

CUR B

WDR R

WDR G

WDR B

0 ~ 511

0 ~ 511

0 ~ 511

0 ~ 511

0 ~ 511

0 ~ 511

50

50

50

380

380

380

Range

DATA

White Balance Color analyzer

White Balance Initial Data

This manual is related to the following products: