beautypg.com

Installation, Technical specifications – Lincoln Electric POWER WAVE F355I User Manual

Page 8

background image

A-1

INSTALLATION

POWER WAVE F355i

A-1

TECHNICAL SPECIFICATIONS -

POWER WAVE F355i

INPUT AC VOLTAGE & DC OUTPUT

Product

Ordering

Input AC

Rated DC Output Output

Weight Dimensions

Name Information Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

(continuous)

POWER

K2156-1

380-400/

350A / 34V / 60%

14.6” x 17.2” x 27.6”*

WAVE

415-460/

AMPS

(100.0 lbs.)

(371 x 437 x 701*)mm

F355i

K2156-2

575

5-425

(45.4 kg.)

300A / 32V /100%

* Includes Mounting

60/50 Hz

Brackets

3 Phase

* Overall Length without Mounting Brackets, 21.06” (535mm)

Voltage

380
400
415
460
575

Phases

3
3
3
3
3

300Amps @

32Volts(100%)

23
22
22
19
16

350Amps @

34Volts(60%)

28
27
26
23
18

Line Cord

AWG

10
10
10
10
10

Fuse size

40A
40A
40A
40A
30A

POWER WAVE F355i INPUT CURRENT

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

100%

60%

CURRENT

300
350

LENGTH UP 200FT.(61m)

1/0
1/0

200-250 FT. (61-76m)

1/0
2/0

*

Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.