Table 3, Table 7, Table 4 – Lennox Hearth Electronic LMDV-3530-CNM User Manual
Page 3: Table 5, Table 6, Figure 3 honeywell electronic gas valve, Figure 2, Honeywell millivolt gas valve, Table 1, Table 2
![background image](/manuals/165781/3/background.png)
3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Electronic Models -
Electronic models have a fixed rate gas valve.
Input of electronic models is shown in
Table 3.
Electronic Models with Fixed Rate Gas Valve
Natural and Propane Gas
Model Series
Input Rate
(BTU / HR)
LMDVT-3328
LMDVR-3328
17,500
LMDV-3530
20,000
LMDV-4035
27,000
Table 3
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model
Series
Nat.Gas
drill size (inches)
Propane
drill size (inches)
LMDVT-3328
LMDVR-3328
#45 (.082")
*
39L66 •
(.048")
*
99K780 •
LMDV-3530
#44 (.086")
*
60J8001 •
#55 (.052")
*
19L5201 •
LMDV-4035
#37 (.104")
*
24M1001 •
1/16" (.062")
*
21L0101 •
Table 7
Inlet Gas Supply Pressure
(all models)
Fuel #
Minimum
Maximum
Natural Gas
5.0" WC
(1.24 kPa)
10.5" WC
(2.61 kPa)
Propane
11.0" WC
(2.74 kPa)
13.0" WC
(3.23 kPa)
Table 4
Gas Pressure - All Models
Tables 4, 5 and 6 show the appliances' gas
pressure requirements:
Manifold Gas Supply Pressure
(millivolt models)
Fuel #
Low
High
Natural
Gas
(Lo) 2.2" WC
(.55 kPa)
(Hi) 3.5" WC
(.87 kPa)
Propane (Lo) 6.3" WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 5
Manifold Gas Supply Pressure
(electronic models)
Fuel #
Maximum Manifold Pressure
Natural Gas
(Hi) 3.5" WC (.87 kPa)
Propane
(Hi) 10.0" WC (2.49 kPa)
Table 6
Test gauge connections are provided on the
front of the millivolt gas control valve, identi-
fied IN for the inlet and OUT for the manifold
side. A 1/8" NPT Test gauge connection
is provided at the inlet and outlet side of
the electronic gas control valve.
Orifice Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 7). For
elevations above 4500 feet, contact your gas
supplier or qualified service technician .
Gas Valve Diagrams
See Figures 1 & 2 for Millivolt models and
Figure 3 For Electronic Models.
Figure 3
Honeywell Electronic Gas Valve
FF
O
NI
P
S
I
N
O
L
O
RT
N
O
C
GI
N
TIER
Manifold Pressure
Port
ON / OFF Switch
Inlet
Pressure
Port
Electronic
Gas
Control
Valve
O N
OFF
PIL
OT
LO
H
I
Figure 2
GAS CONTROL
KNOB
CONVERTIBLE
HI/LO REGULATOR
(adjusts flame height
and heat output)
INLET
PRESSURE
TAP
PILOT
ADJUSTMENT
SCREW
WIRING
TERM-
INALS
OUTLET
PRESSURE
TAP
TP/TH
PIEZO
IGNITER
TH
TP
Honeywell Millivolt Gas Valve
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).
These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than 1/2 psig (3.5 kPa).
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA 54
/ ANSI Z223.1 - latest edition or, in Canada, the
CAN1-B149.1 and .2 codes - latest edition.
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
NATURAL GAS
Models
Input Rate (BTU / HR)
LMDVT-3328CNM
LMDVR-3328CNM
17,500 high
11,700 low
LMDV-3530CNM
20,000 high
12,800 low
LMDV-4035CNM
27,000 high
18,500 low
Table 1
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
PROPANE GAS
Models
Input Rate (BTU / HR)
LMDVT-3328CPM
LMDVR-3328CPM
17,500 high
14,000 low
LMDV-3530CPM
20,000 high
15,200 low
LMDV-4035CPM
27,000 high
21,500 low
Table 2
HI
LO W
HT
PT
HT
PT
PILO
T
PIL
OT
ON
it
OFF
IN
OUT
Manifold Pressure Tap
Inlet Pressure Tap
SIT Millivolt Gas Valve
Pilot Adjustment
Screw
HI/LO Variable
Flame Height
Adjustment
Main Gas
Control Knob
OFF/PILOT/ON
Figure 1
* Standard size installed at factory
• Part /Cat. Number