Operation, Saturday – Lennox International Inc. 43558 User Manual
Page 20
38
38
OPERATION
Stage 1 Light
This LED will turn on in GREEN when the first stage of heat or cool is activated.
When in Emergency Heat mode, this LED will turn on in RED when the first stage of
emergency heat is activated.
Stage 2 Light
This LED will turn ON in YELLOW when the second stage of heat, emergency heat or
cool is activated.
The Stage 1/Emergency and Stage 2 LED’s will flash On/Off when the corresponding stage is being held off tem-
porarily. For example, during a compressor delay.
Emergency Heat
System Indicator Light (continued)
1
•
em
2
When the Power Switch is in the “em” position, the thermostat
is placed in the Emergency Heat mode. The compressor will not
operate in this mode and only auxiliary heat will be used.
When Emergency Heat is selected on a multi-stage system, both
stages of heat operate at the same time. So, the heating acts like
a single-stage system.
NOTE:
Emergency Heat Mode is not an energy saving set-
ting, so use only when necessary.
41653_model43558.pmd
39
39
Reviewing the Current Temperature Setting
■ Current time and temperature.
■ Thermostat is set to AUTO and the heating system is selected.
■ Press for 1 second or less.
■ Set Temperature is shown beside current room temperature.
■ If held for over 1 second, Temporary Manual Override mode is entered.
Refer to the next section.
Saturday
PM
System
Fan
Temp
4
Saturday
Set Temp
System
Fan
Temp
4
or