Logicube Omniclone Xi User Manual
Page 39
![background image](/manuals/165653/39/background.png)
THE DATABASE/BARCODE OPTION
Logicube Omniclone Xi ™ User’s Manual
33
Breakdown of Config.txt
Information collected by the Database option is
governed by a “Config List”. This list contains all
of the items that the Database will record. It also
indicates whether or not the Barcode Scanner is
used. Config lists can be created with the
Omniclone-Xi™, (or from a text editor like
Notepad.exe). The lists are stored together in a file
called Config.txt. This file is stored on the CF
drive.
A Config List with all of the options chosen looks
like the list below:
[Title]
IncludeHeaders
UnitSN
UnitFirmware
Scan1-OperatorBadge
Scan2-BatchNo
Scan3-Location
Time
Date
MasterModel
MasterSerial
TargetModels
TargetSerials
Mode
Outcome
[Title] - This is a user-entered name for the Config
List. The name should be 18 characters or less.
IncludeHeaders – If this line is included, it tells the
database to put headers as the first line of data in
the Database.csv file.
UnitSN – This is the serial number of the
Omniclone-Xi™ unit.
UnitFirmware – This is the Omniclone-Xi’s current
Firmware.
Scan1-UserEnteredName1 – This is the first line of
information collected by the Barcode Scanner (i.e.
Operator’s Badge Number). The entered name
needs to be 18 characters or less.