A-2

A-2

INSTALLATION

Read entire installation section before starting
installation.

SAFETY PRECAUTIONS

IDENTIFY AND LOCATE
COMPONENTS

If you have not already done so, unpack the SP 170-I
from its carton and remove all packing material
around the SP 170-I. Remove the following loose
items from the carton (see Figure A.1):

1. SP 170-I

2. Gun and cable assembly

(1)

3. Literature and miscellaneous including:

a) This operating manual

b) Contact tips:

SP 170-I

2

.025

(0.6mm) for solid wire

2

.030

(0.8mm) for solid wire

1

.035

(0.9mm) for cored wire

c) 5/64

(2.0 mm) Hex key wrench for removal of

drive roll.

4. 10 ft (3,0 m) work cable.

5. Work clamp.

6. 14.0 ft (4.3 m) .19

(4.8 mm) dia. gas hose

7. 2- Hose clamps

8. Gas nozzle

(1)

The gun is ready to feed .035" (0.9mm) diameter.

ELECTRIC SHOCK can kill.

Only qualified personnel should perform

this installation.

Only personnel that have read and under-

stood the SP 170-I Operating Manual
should install and operate this equipment.

Machine must be plugged into a receptacle

which is grounded per any national, local
or other applicable electrical codes.

The SP 170-I power switch is to be in the

OFF (

O

) position when installing work

cable and gun and when connecting power
cord to input power.

WARNING

FIGURE A.1

SP 170 -I

E

WELDING

WELD

ING AMP

AMP RANGE

RANG

E

1

2

4

6

7

8

3

5

SP 170-I