5

Gate Control

Refer to Figure 5 for an outline of a typical gate installation.

❑ Route four wires between the gate and the keypad (two for

power, two for control).

❑ Connect the gate operator’s auxiliary or radio power output

terminals to the keypads POWER input terminals (observe
wiring polarity).

❑ Connect the gate operator’s OPEN terminals to the keypad’s

Relay #1 COMMON & N.O. terminals.

NOTE: For operator wiring specifi cs, refer to the gate

operator’s wiring diagram.

❑ If a request-to-enter pushbutton or fi re access keyswitch is

going to be used, route two wires from the keypad to the
normally open switch. Connect the wires to the normally
open switch and to the keypad’s REQUEST-TO-ENTER and
COMMON terminals.

❑ If an inhibit switch or timer is going to be used, route two

wires from the keypad to the inhibit switch or timer relay.
Connect the inhibit switch/timer terminals to the keypad’s
INHIBIT and COMMON terminals.

NOTE: If the INHIBIT input is going to be used, it must be

programmed to select that input type. See the Programming
Options section of this manual

AKR-1
KEYPAD

FIRE
ACCESS
KEYSWITCH

2 WIRES FROM OPERATOR
FOR AKR-1 POWER

GATE
OPERATOR
(BEHIND GATE)

2 WIRES FROM AKR-1
TO TRIGGER GATE OPEN

2 WIRES FOR
REQUEST-TO-ENTER

Figure 5. Gate Installation

217350 D IMAGE 7