19. OPTIONAL OUTPUT CONNECTIONS

20. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS

17. SPEAKERPHONE OPERATION

18. SUPERVISORY CONDITIONS

PROGRAM THE CONSOLE TO ENABLE SPEAKERPHONE MODE
NOTE: SPEAKERPHONE MODE CAN ONLY BE USED ON INCOMING CALLS
AND WILL NOT FUNCTION WHEN THE CONSOLE IS OPERATING FROM
BACKUP BATTERY POWER. ATTEMPTING TO ANSWER WHILE THE CONSOLE
IS ON BACKUP POWER WILL CAUSE AN EMERGENCY ALARM.

WHILE THE TELEPHONE IS RINGING, ACTIVATING AN EMERGENCY
TRANSMITTER OR PRESSING THE HELP BUTTON WILL SEIZE THE
TELEPHONE LINE

THE SYSTEM WILL BEGIN 2-WAY VOICE ACTIVATED MODE FOR AUDIO
COMMUNICATIONS

THE CONSOLE WILL END AUDIO COMMUNICATIONS WHEN EITHER:

• THE HELP BUTTON IS PRESSED
• ANY EMERGENCY TRANSMITTER IS ACTIVATED
• THE AUTO-DISCONNECT TIMER RUNS OUT (PROGRAMMABLE
FOR 15, 30, OR 60 MINUTES)

1

2

3

4

WARNING: THE CONSOLE WILL NOT BE ABLE
TO REPORT AN EMERGENCY WHILE THE
SPEAKERPHONE MODE IS ACTIVE

NOTE: TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE,
PRESS EITHER THE HELP BUTTON OR THE BUTTON ON AN EMERGENCY
TRANSMITTER TO END THE PHONE CALL AND THEN PRESS ONE OF THESE
BUTTONS AGAIN TO REPORT THE EMERGENCY.

1 - +12 VDC @ 100 mA

2

- RELAY NORMALLY OPEN

3 - RELAY NORMALLY OPEN

4 - COMMON GROUND

5 - EXTERNAL SPEAKER

TERMINALS 2 & 3
ARE A FORM "A" DRY
CONTACT RELAY
RATED 24 VOLTS AT
1 AMP MAXIMUM

NOISEMAKER OR

VISUAL INDICATOR

EXTERNAL

POWER SUPPLY

CONSOLE

TERMINAL BLOCK

CONNECT WIRES TO
RELAY TERMINALS

USE A SMALL
SCREWDRIVER
TO PUSH ON THE
TERMINAL LOCKS
TO ALLOW THE
WIRE TO SLIDE
INTO THE TERMINAL
HOLE

NOTE: THE CONSOLE IS SHIPPED WITH
REMOVABLE LABELS COVERING SOME
OF THE REAR CONNECTIONS

TERMINALS 4 & 5
HAVE A FACTORY
INSTALLED JUMPER
DO NOT REMOVE
UNLESS USING
A UL LISTED MODEL
RSM-1 OR OTHER
UL LISTED SPEAKER

NOTE: NOT TO BE USED IN

UL INSTALLATIONS

5 - EXTERNAL SPEAKER

GROUND

3 - RELAY NORMALLY OPEN

2 - RELAY NORMALLY OPEN

1 - +12 VDC @ 100 Ma

CONSOLE MAIN

TERMINAL BLOCK

CONSOLE MIC TERMINALS

EXTERNAL MICROPHONE (+)

MICROPHONE COMMON (-)

LINEAR
MODEL RSM-1

RSM-1 TERMINAL BLOCK

SPKR

SPKR

MIC (-)

MIC (+)

RSM-1

TERMINALS

NOTE: REMOVE
JUMPER WHEN

USING A UL

LISTED MODEL

RSM-1 OR OTHER

UL LISTED

SPEAKER

4 -

REMOVE

JUMPER

WIRE

USE

SHIELDED

TWISTED PAIR

WIRE FOR

MICROPHONE

SHIELD

WIRE

NOTE: NOT TO BE USED IN

UL INSTALLATIONS

TRANSMITTER LOW BATTERY

TRANSMITTER SUPERVISORY

WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE
CONSOLE'S STATUS INDICATOR WILL BLINK SLOWLY

IF A TRANSMITTER PROGRAMMED AS SUPERVISED FAILS
TO REPORT STATUS IN A 24 HOUR PERIOD, THE CONSOLE'S
STATUS INDICATOR WILL LIGHT

LOW CONSOLE BACKUP BATTERY
THE CONSOLE WILL TEST ITS BACKUP
BATTERY EVERY 8 HOURS. IF THE BATTERY
TESTS LOW, THE POWER INDICATOR WILL
BLINK SLOWLY WHILE THE CONSOLE
CHARGES THE BATTERY.

CLEARING STATUS INDICATIONS

PRESS THE CANCEL BUTTON TO
CLEAR THE STATUS INDICATOR
AND STOP THE ANNUNCIATION

THE CONSOLE WILL REPORT THESE SUPERVISORY CONDITIONS
TO THE CENTRAL STATION IF ENABLED IN THE COMMUNICATOR
PROGRAMMING (AUTOMATIC FULL-SYSTEM CONSOLE SUPERVISORY
REPORTS CAN ALSO BE SENT AT 1, 7, OR 30 DAY INTERVALS)

NOTE: A TROUBLE

CONDITION WILL LIKELY OCCUR AGAIN

UNTIL THE PROBLEM IS FIXED

WHEN TROUBLE EXISTS,

THE CONSOLE WILL ANNOUNCE

THE CONDITION EVERY

HOUR UNTIL CLEARED