Compact Fluorescent
Zonal Lumens and Percentages
Zone
Lumens
% Lamp
%Luminaire
0-30
391
16.32
48.98
0-40
576
24.04
72.12
0-60
749
31.23
93.72
0-90
799
33.33
100.00
40-90
223
9.29
27.88
60-90
50
2.09
6.28
90-180
0
.00
.00
0-180
799
33.33
100.00
** Efficiency = = 33.3% **
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .40 .40 .40 .40 .39 .39 .39 .39 .37 .37 .37 .35 .35 .35 .34 .34 .34 .33
1 .38 .36 .36 .35 .37 .36 .35 .34 .34 .34 .33 .33 .33 .32 .32 .32 .31 .31
2 .35 .34 .32 .31 .35 .33 .32 .31 .32 .31 .30 .31 .30 .29 .30 .29 .29 .28
3 .33 .31 .29 .28 .33 .31 .29 .28 .30 .28 .27 .29 .28 .27 .28 .27 .26 .26
4 .32 .29 .27 .25 .31 .28 .27 .25 .28 .26 .25 .27 .26 .24 .26 .25 .24 .24
5 .30 .27 .24 .23 .29 .26 .24 .23 .26 .24 .23 .25 .24 .22 .25 .23 .22 .22
6 .28 .25 .23 .21 .27 .24 .22 .21 .24 .22 .21 .23 .22 .21 .23 .22 .20 .20
7 .26 .23 .21 .19 .26 .23 .21 .19 .22 .20 .19 .22 .20 .19 .21 .20 .19 .18
8 .25 .21 .19 .18 .24 .21 .19 .17 .21 .19 .17 .20 .19 .17 .20 .18 .17 .17
9 .23 .20 .17 .16 .23 .19 .17 .16 .19 .17 .16 .19 .17 .16 .18 .17 .16 .15
10 .22 .18 .16 .15 .21 .18 .16 .15 .18 .16 .15 .17 .16 .14 .17 .16 .14 .14
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 38.0
8091DCL-D6A03
Certified Test Report no. 3519FR
Computed by LSI Program **TEST-LITE**
SC(ALONG) = 1.0, SC(ACROSS) = 1.1
Prepared For:
Lightolier
Fall River, MA
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
300
600
0°
30°
60°
90°
150
400
Calculite 6” Vetro Horizontal Downlight, Cat.# 8091DCL/D6A03,
Opal Lens 32W Sylvania Dulux T/E Triple Tube.
Lumen Rating = 2400 LMS. Universal Ballast #C2642UNVBES(#1)
Candlepower Summary
Angle Along 22.5
45
67.5
Across
Output
Lumens
0
549
549
549
549
549
5
548
545
543
545
549
52
10
536
534
533
534
538
15
513
511
509
512
517
144
20
478
475
474
478
483
25
426
423
421
428
434
196
30
362
360
360
367
371
35
290
289
292
299
305
185
40
220
220
224
232
238
45
158
157
162
168
171
127
50
105
105
105
104
104
55
34
34
35
35
36
46
60
30
29
30
29
29
65
26
26
26
26
26
26
70
22
21
21
21
21
75
15
15
15
15
15
17
80
11
11
11
11
11
85
8
7
7
7
7
8
90
4
4
4
4
4
Calculite 6” Dia. Recessed Horizontal Vetro Downlight,
Cat.# 8031CL/D6A03 32W Sylvania Dulux T/E Triple Tube.
Lumen Rating = 2400 LMS. Universal Ballast #C2642UNVBES(#1)
Candlepower Summary
Angle
Along
22.5.
45
67.5
Across.
Output
Lumens
0
543
543
543
543
543
5
536
541
550
555
562
53
10
565
572
577
567
558
15
595
594
586
572
569
164
20
565
575
574
568
583
25
543
557
528
560
584
253
30
496
511
507
508
524
35
410
431
445
487
514
277
40
308
308
337
374
406
45
216
213
206
202
211
174
50
160
154
142
123
111
55
79
72
62
60
61
67
60
28
28
28
29
30
65
24
24
24
25
26
24
70
20
20
20
21
21
75
14
15
15
15
16
16
80
11
11
11
11
12
85
8
7
7
8
8
8
90
4
4
4
5
5
300
600
0°
30°
60°
90°
150
450
8031CL-D6A03
Certified Test Report no. 3535FR
Computed by LSI Program **TEST-LITE**
SC(ALONG) = 1.3, SC(ACROSS) = 1.4
Prepared For:
Lightolier
Fall River, MA
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
Zonal Lumens and Percentages
Zone
Lumens
% Lamp %Luminaire
0-30
469
19.55
45.26
0-40
746
31.10
71.99
0-60
987
41.16
95.27
0-90
1036
43.20
100.00
40-90
290
12.10
28.01
60-90
49
2.04
4.73
90-180
0
.00
.00
0-180
1036
43.20
100.00
** Efficiency = 43.2% **
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .51 .51 .51 .51 .50 .50 .50 .50 .48 .48 .48 .46 .46 .46 .44 .44 .44 .43
1 .49 .47 .46 .45 .48 .46 .45 .44 .45 .44 .43 .43 .42 .42 .41 .41 .40 .40
2 .46 .44 .42 .40 .45 .43 .41 .40 .41 .40 .39 .40 .39 .38 .39 .38 .37 .36
3 .43 .40 .38 .36 .42 .39 .37 .35 .38 .36 .35 .37 .36 .34 .36 .35 .34 .33
4 .41 .37 .34 .32 .40 .37 .34 .32 .36 .33 .32 .35 .33 .31 .34 .32 .31 .30
5 .38 .34 .31 .29 .37 .34 .31 .29 .33 .31 .29 .32 .30 .29 .32 .30 .28 .28
6 .36 .32 .29 .27 .35 .31 .28 .26 .31 .28 .26 .30 .28 .26 .29 .27 .26 .25
7 .34 .29 .26 .24 .33 .29 .26 .24 .28 .26 .24 .27 .25 .24 .27 .25 .23 .23
8 .31 .27 .24 .22 .31 .26 .24 .22 .26 .23 .22 .25 .23 .21 .25 .23 .21 .21
9 .29 .25 .22 .20 .29 .24 .22 .20 .24 .21 .19 .23 .21 .19 .23 .21 .19 .19
10 .27 .23 .20 .18 .27 .22 .20 .18 .22 .19 .18 .22 .19 .18 .21 .19 .17 .17
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 36.0