Operation, Caution – Lincoln Electric EAGLETM 10 User Manual
Page 18

“
RANGE” SWITCH
The “Range” switch is used to select one of four
amperage ranges with generous overlap for Stick/TIG
welding.
Never change the “RANGE” Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
“
CONTROL” DIAL
Provides a fine welding current adjustment within the
Range Switch settings in the STICK mode and weld-
ing voltage control with the Range switch set in the
wire feed mode.
Process Range Setting Current Range
B-2
OPERATION
B-2
EAGLE™ 10,000 PLUS
CAUTION
KOHLER
23 H.P. COMMAND CH23S
.40 Gallons/Hour
(1.50 Liters/Hour)
.7 Gallons/Hour
(2.8 Liters/Hour)
1.3 Gallons/Hour
(4.9 Liters/Hour)
1.4 Gallons/Hour)
(5.3 Liters/Hour)
Low Idle - No Load
2400 RPM
High Idle - No Load
3700 RPM
DC CC Weld Output
210 Amps @ 25 Volts
Auxiliary Power
9000 Watts
EAGLE™ 10,000 PLUS APPROXIMATE FUEL CONSUMPTION
STICK/TIG
(Constant current)
(3 range settings)
90 Max.
145 Max.
225 MAX.
40 to 90 Amps
70 to 145 Amps
120 to 225 Amps