–35–

2-1) Indoor fan does not operate

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

Is the unit

operating?

Is the DC5V

at 20pin of

(MICOM)?

Is the DC5V

at 21pin of

(MICOM)?

Is the DC5V

at 22pin of

(MICOM)?

Is the DC12V

at each terminal

RY- Mid Coil

Is the DC12V

at each terminal

RY-S/High Coil

Is the

AC220V(240V) between

"C" and "S/High" of

P.C.B?

Is the

AC220V(240V) between

"C" and "High" of P.C.B?

Is the

AC220V(240V)

between "C" and "Mid"

of P.C.B?

Replacement ICO3M

Replacement S/High

Check the motor winding

Replacement High

Replacement RY-Mid

Is the DC12V

at each terminal

RY-High Coil

Replacement

(MICOM) and

check the EVA-Th.

Reset the power ON/OFF S/W