Installation instructions – LG LDG3015ST User Manual

Page 8

background image

8

INSTALLATION INSTRUCTIONS

Your range is designed to operate at a pressure of

5” of water column on natural gas or 10” of water

column on LP.
Make sure you are supplying your range with the type

of gas for which it is configured.
This range is convertible for use on natural or LP gas.

When using this range on LP gas, conversion must be

made by a qualified LP installer before attempting to

operate the range.
For proper operation, the pressure of natural gas

supplied to the regulator must be between 5” and 13”

of water column.

For LP gas, the pressure supplied to the regulator

must be between 10” and 13” of water column.
When checking for correct operation of the regulator,

the inlet pressure must be at least 1” more than the

operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the

range must remain in the supply line regardless of

which type of gas is being used.
A flexible metal appliance connector used to connect

the range to the gas supply line should have an I.D. of

5/8” and a max of 5ft. In Canada, flexible connectors

must be single wall metal connectors less than 6 feet

in length.

GAS PIPE AND ELECTRICAL OUTLET LOCATIONS

1. PROVIDE ADEQUATE GAS SUPPLY

14

5/16

2”

3”

Recommended area for 120V

outlet on rear wall and area for

through-the wall connection of

pipe stub and shut-off valve.

Recommended area for

through-the floor connection

of pipe stub and shut-off valve.

30”

9

1/16

8

19/32

2

3/8

11

3/32