Logitek Standard Elec. Cable Manufacturing C/A210 User Manual

Page 8

background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

C

himney

r

equirements

The Performer™ C/A210 inserts are approved for use in

masonry fireplaces built to UBC Chapter 37 or equivalent

with a minimum 22” (559mm) opening at the front of the

fireplace.

These heaters are designed to be installed into an existing

masonry fireplace (built to UBC 37 or ULC S628 standards)

or factory-built, solid-fuel and wood-burning fireplaces (listed

to UL 127 or ULC S610) only.

Do not remove brick or mortar from masonry fireplace to

accommodate insert. Do not remove brick or mortar from
masonry fireplace to accommodate insert. Approved with or
without positive flue connection. Approved with minimum
6” (152mm) diameter stainless steel listed reline system.
Ask your dealer for recommended chimney size. Country
Collection inserts are tested to UL 1482 / ULC S628-93 and
listed by OMNI-Test Laboratories, Inc.; Beaverton, OR.

Remove and clean behind unit frequently, as creosote build

up may occur rapidly.

i

nstallation

P

roCeDures

- m

asonry

C

himney

Note: Although not required, a full-length stainless steel liner

is recommended for optimum safety and performance. See

your Lennox Hearth Products dealer for details.

Note: When installing your stove with a positive flue connec-

tion, be sure to leave the insulation off the surround panels

(flanges) and leave a 1/4” (6mm) airspace insulation off the

surround panels and the facing of your fireplace.

1. READ ENTIRE INSTALLATION INSTRUCTIONS.

2. Check all REQUIRED CLEARANCES as specified in the

previous section (page 7) of this installation instruction

booklet.

3. Wear gloves during installation in case of sharp edges on

the stove and it’s parts

4. Determine the depth of the fireplace lintel. The lintel is

the masonry area over the fireplace opening, and is sup-

ported by a noncombustible plate, usually of steel. The

depth may vary from a single brick width (4”/102mm)

to that of several brick. If any portion of the flue collar

opening on top of the insert (as shown in the diagram

below) will project under the lintel area, a deflector plate

must be mechanically attached to the fireplace insert to

divert heat and gases away from the lintel.

Consult your dealer for the correct attachment piece.

Compare lintel depth to the distance from the flue collar

opening to the fireplace to determine if this caution per-

tains to your installation. If there is sufficient clearance,

a flue offset may also be used. Consult your dealer.

5. Open or remove the existing fireplace damper. Make sure

the damper cannot fall closed.

6. Install the two 1/2” x 3” (13mm x 76mm) leveling bolts

-heads up- a few turns in the leveling nuts on each side

of the outer chamber of the insert at the lower rear cor-

ners.

7. Position the insert in the center of the fireplace opening

and push it back until the surround brackets are approxi-

mately 2” (51mm) away from the fireplace front.

8. Install the side surround panels and push the insert up

snug against the fireplace face. Then with the location

selected remove the surround panels and level the stove

with the leveling bolts using a 3/4” (19mm) socket, exten-

sions (to reach the bolt head), and a ratchet.

9. Glue the insulation around the outer edge of both the top

and side surround panels.

10. Install the surround panels loosely, align and tighten.

Check for a tight fit against the fireplace.

11.Install the brick and baffle as per instructions on page

6.

POSITIVE FLUE CONNECTION: See your authorized Len-

nox Hearth Products dealer for necessary accessories and

installation instructions.

Positive flue connectors required for installation in Canada

are available from your Lennox Hearth Products dealer.

Please use the part number indicated below.

71161 - 6" Positive Flue Connector Ring Kit

Lintel

Flue Outlet

Not to Scale

Brick Face

Insert Surround

Smoke

Deflector

Mechanically

Attached to

Insert

Figure 7