5.2.4 AUDIBLE SIGNALS
TONE / RING
CADENCE
Alarm Ring, Continuous
0.2 sec ON / 0.2 sec OFF Repeat
Alarm Ring, Single
1 sec ON
All Call Page Tone
1 sec ON
Australia
0.35 sec ON / 0.35 sec OFF Repeat
Finland, EU
0.3 sec ON / 0.3 sec OFF Repeat
Spain
0.2 sec ON / 0.2 sec OFF Repeat
Sweden
Denmark
0.25 sec ON / 0.25 sec OFF Repeat
Busy Tone
Others
0.5 sec ON / 0.5 sec OFF Repeat
New Zealand 1 sec ON / 3 sec OFF Repeat
CO Ring Back Tone
Others
1 sec ON / 2 sec OFF Repeat
Finland
Italy
1 sec ON / 4 sec OFF Repeat
CO Ring
Others
0.4 sec ON / 0.4 sec OFF / 0.4 sec ON / 2 sec OFF Repeat
LCR Dummy CO Dial Tone
Continuous
Confirm Tone
1.2 sec ON
DND Tone
0.2 sec ON / 0.2 sec OFF / 0.2 sec ON / 0.2 sec OFF / 0.2 sec
ON / 0.5 sec OFF Repeat
Finland
0.2 sec ON / 0.3 sec OFF / 0.2 sec ON / 0.3 sec OFF / 0.2 sec
ON / 0.8 sec OFF Repeat
EU
0.2 sec ON / 0.3 sec OFF / 0.7 sec ON / 0.8 sec Off Repeat
Dial Tone
Others Continuous
Australia
2.5 sec ON / 0.5 sec OFF Repeat
Finland
Italy
0.2 sec ON / 0.2 sec OFF Repeat
Spain
0.6 sec ON / 1 sec OFF Repeat
Sweden
0.25 sec ON / 0.75 sec OFF Repeat
Error Tone
Others
0.25 sec ON / 0.25 sec OFF Repeat
HFTB Warning Tone
0.2 sec ON / 0.2 sec OFF 3 Times
Finland
0.6 sec ON / 0.2 sec OFF / 0.6 sec ON / 4 sec OFF Repeat
Italy
0.6 sec ON / 0.2 sec OFF / 0.2 sec ON / 4 sec OFF Repeat
Intercom Ring
Others
0.8 sec ON / 2.4 sec OFF Repeat
Reminder Tone
0.5 sec ON / 0.5 sec OFF 3 Times
Australia
New Zealand
0.4 sec ON / 0.2 sec OFF / 0.4 sec ON / 2 sec OFF Repeat
Denmark
Finland
EU
Italy
Netherlands
Norway
1 sec ON / 4 sec OFF Repeat
Spain
1.5 sec ON / 3 sec OFF Repeat
Sweden
1 sec ON / 5 sec OFF Repeat
Ring Back Tone
Others
1 sec ON / 2 sec OFF Repeat
- SLT
SLT RING
CADENCE
Finland, Italy
1 sec ON / 4 sec OFF Repeat
New Zealand 0.4 sec ON / 0.2 sec OFF / 0.4 sec ON / 2 sec OFF Repeat
Spain
1 sec ON / 3 sec OFF Repeat
SLT CO Ring
Others
0.4 sec ON / 0.2 sec OFF / 0.4 sec ON / 4 sec OFF Repeat
Finland
0.4 sec ON / 0.2 sec OFF / 0.4 sec ON / 4 sec OFF Repeat
Italy
0.6 sec ON / 0.2 sec OFF / 0.2 sec ON / 4 sec OFF Repeat
New Zealand 1 sec ON / 2 sec OFF Repeat
Spain
0.4 sec ON / 0.2 sec OFF / 0.4 sec ON / 3 sec OFF Repeat
SLT Intercom Ring
Others
1 sec ON / 4 sec OFF Repeat