Ratings

Notes:

1.

The ratings are based on standard test procedures
prescribed by the United States Department of Energy.

2.

Net I=B=R ratings are based on net installed radiation of
sufficient quantity for the requirements of the building and
nothing need be added for normal piping and pickup.
Ratings are based on a piping and pickup allowance of 1.15.

3.

Use only the vent materials and methods specified in the
Installation and Service Manual.

4.

The Solution is orificed for operation up to 2000 feet
altitude. The ap pli ance will be derated 4% per 1000 feet
above 2000 feet el

e

va

tion. Consult the factory for

installations above 2000 feet elevation.

5.

Ratings have been confirmed by the Hydronics Institute,
Section of AHRI.

Maximum allowed working pressure is located on the rating plate.

NOTICE

Installation & Service Manual

Solution Boiler

I=B=R Rating

Model Number

Note: Change “N” to

“L” for L.P. gas models.

Input
MBH

(Note 4)

Min Max

Gross

Output

MBH

(Note 1,5)

Net

I=B=R

Ratings

Water,

MBH

(Note 1,5)

CBN045

23

45

37

32

CBN075

38

75

62

54

CBN090

45

90

75

65

CBN135

68

135

112

97

CBN180

90

180

149

130

CBN215

108

215

178

155

CBN260

130

260

216

188

Other Specifications

Boiler Water

Content

Gallons

Water

Connections

Gas

Connections

Vent

Size

(Note 3)

0.87

1 1/2"

1/2"

4"

0.91

1 1/2"

1/2"

5"

0.91

1 1/2"

1/2"

5"

0.95

1 1/2"

1/2"

6"

0.99

1 1/2"

3/4"

7"

1.02

1 1/2"

3/4"

7"

1.06

2"

3/4"

8"

Figure A High Altitude Label Location

UNIT EQUIPPED FOR

HIGH ALTITUDE

UP TO 2000 FT.