beautypg.com

Installation, Technical specifications - classic® 300d kubota – Lincoln Electric CLASSIC 300 D User Manual

Page 8

background image

INSTALLATION

CLASSIC® 300D KUBOTA

A-1

A-1

TECHNICAL SPECIFICATIONS - CLASSIC® 300D KUBOTA

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

System

4 Cylinder
4 Cycle

148.53 cu. in

12VDC battery

Fuel: 15 gal.

Naturally Aspirated

(2.43 ltrs)

(Group 24, 650

57 L

Kubota

Water-Cooled

High Idle 1800

cold crank amps)

V2403M

Diesel Engine

Low Idle 1400

Bore x Stroke

1.4 KW Starter

Oil: 10.04 Qts.

Tier 4 interim

Cast Iron Cylinder, Full Load 1800

40 A. Alternator

9.5 L

Compliant

Block/Crankcase

3.43” x 4.03”

w/ built in reg. Coolant:

32.5HP @1800 RPM

9.5 Qts.
9.0 L

INPUT - DIESEL ENGINE

RATED OUTPUT @ 104°F(40°C) - WELDER

MODEL

HEIGHT WIDTH

DEPTH

WEIGHT

K1643-9 CSA@

1320 lbs.

With Out

(599 kg)

Wire Feed Module

45.5 in.

24.00 in.

66.36 in.

K1643-10 CSA @

(1156 mm)

(610 mm)

(1686 mm)

1355 lbs.

With Wire Feed Module

(615 kg)

RATED OUTPUT @ 104°F(40°C) - GENERATOR

DESCRIPTION

RATED DC OUTPUT*

Duty

DC CURRENT RANGE

VOLTS @ RATED AMPS

CYCLE

Fine Adjustments in each Range

40-350 Amps

220-Max.

300 Amp DC Welder

30V @ 250A

100%

160-240

All Copper Windings

32V @ 300A

60%

120-190

Pure DC Power Generator

99V DC Max. OCV @ 1800RPM

80-130

Min.-90

Auxiliary Power

(1)

3,000 Watts Continuous, 60 Hz AC

26 Amps @ 115V
13 Amps @ 230V

PHYSICAL DIMENSIONS

(2)

*

Based on a 10 min. period.

(1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to

rated capacity. When welding, available auxiliary power will be reduced.

(2) Height to top of exhaust elbow.