System adjustments – Linear RE-1 User Manual
Page 26
24
Keypad Beeps On/Off
Default: On
The default setting causes the main keypad to beep when each key is
pressed. The beeps can be disabled.
Press:
Keypad Beeps
Keypad Beeps: 0 = Beeps OFF
1 = Beeps ON
Relay #1 Tone On/Off
Default: Off
The default setting does not cause the annunciator to sound when Relay #1
is activated. The Relay #1 activation tone can be enabled.
Press:
Relay #1 Tone
Relay #1 Tone: 0 = Tone OFF
1 = Tone ON
Relay #2 Tone On/Off
Default: Off
The default setting does not cause the annunciator to sound when Relay #2
is activated. The Relay #2 activation tone can be enabled.
Press:
Relay #2 Tone
Relay #2 Tone: 0 = Tone OFF
1 = Tone ON
Relay Tone Duration
Default: 1 Second
The default setting causes the annunciator to sound for 1 second when
Relay #1 or Relay #2 is activated (if the tones are enabled). The length of
the activation annunciation can be changed.
Press:
Tone Length
Tone Length = Tone length in Seconds 1-15
Voice Synthesizer On/Off
Default: On
When the voice synthesizer is on the RE-1 will sound voice prompts during
operation and programming. If the voice synthesizer is off, the system will
sound beeps to indicate conditions. The HELP button will announce “Enter
code or press call button to contact resident” regardless of this setting.
The beeps produced when the voice synthesizer is off are:
• 1 Short beep — Keypad key pressed
• 2 Short beeps — Programming entry was valid
• 1 Long beep — Programming entry was invalid
Press:
Voice
Voice: 0 = Voice synthesizer OFF
1 = Voice synthesizer ON
Automatic Daylight Saving Time Clock Adjustment On/Off Default: On
The RE-1’s internal clock used for controlling system functions and time
stamping of the event log automatically adjusts for daylight saving time.
The time will change on the fi rst Sunday in April, and on the last Sunday of
October. For areas where daylight saving time is not observed, this feature
may be disabled.
Press:
Daylight Saving
Daylight Saving: 0 = Daylight Saving Adjust OFF
1 = Daylight Saving Adjust ON
Automatic Door/Gate Open Time
Default: Not Set
Each control relay can be programmed for automatic activation. One or two
Time Zones can be assigned to a relay. The relay will activate and remain
latched during the active period of the Time Zone.
Press:
Relay
1st Time Zone
2nd Time Zone
Relay: 1 = Relay #1
2 = Relay #2
1st Time Zone = Time Zone 1-7
2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)
SYSTEM ADJUSTMENTS
The RE-1 Entry System audio levels can be adjusted to suit the
installation requirements. If required, make these adjustments after
programming, but before closing and securing the RE-1 case.
Speakerphone Volume
The SPEAKERPHONE VOLUME adjustment controls the audio
level that the RE-1 speaker produces during communications
between the visitor and the resident.
✦ NOTE: Adjusting the speaker volume too high will cause the speech
to cut-out as the system switches from talk to listen.
1. Have someone waiting to receive the call. Push the CALL button to
call the residence.
2. Have the resident talk at a normal volume level while adjusting the
SPEAKERPHONE VOLUME control. Adjusting the control clockwise
increases the volume, counterclockwise decreases the volume.
Digital Speech Volume
The DIGITAL SPEECH VOLUME adjustment controls the audio level
of the voice synthesizer. This adjustment effects the audio level of
the voice synthesizer from the speaker and through the telephone.
1. Push
the
HELP button to cause the voice synthesizer to sound the
help message.
2. Adjust
the
DIGITAL SPEECH VOLUME to suit the installation.
Adjusting the control clockwise increases the volume,
counterclockwise decreases the volume.